Surface Induced Dissociation: Dissecting Noncovalent Protein Complexes in the Gas phase
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The quaternary structures of proteins are both important and of interest to chemists, because many proteins exist as complexes in vivo, and probing these structures allows us to better understand their biological functions. Conventional structural biology methods such as X-ray crystallography and nuclear magnetic resonance provide high-resolution information on the structures of protein complexes and are the gold standards in the field. However, other emerging biophysical methods that only provide low-resolution data (e.g. stoichiometry and subunit connectivity) on the structures of the protein complexes are also becoming more important to scientists. Mass spectrometry is one of these approaches that provide lower than atomic structural resolution, but the approach is higher throughput and provides not only better mass information than other techniques but also stoichiometry and topology. Fragile noncovalent interactions within the protein complexes can be preserved in the gas phase of MS under gentle ionization and transfer conditions. Scientists can measure the masses of the complexes with high confidence to reveal the stoichiometry and composition of the proteins. What makes mass spectrometry an even more powerful method is that researchers can further isolate the protein complexes and activate them in the gas phase to release subunits for more structural information. The caveat is that, upon gas-phase activation, the released subunits need to faithfully reflect the native topology so that useful information on the proteins can be extracted from mass spectrometry experiments. Unfortunately, many proteins tend to favor unfolding upon collision with neutral gas (the most common activation method in mass spectrometers). Therefore, this typically results in limited insights on the quaternary structure of the precursor without further manipulation of other experimental factors. Scientists have observed, however, that valuable structural information can be obtained when the gas-phase proteins are activated by collision with a surface. Subcomplexes released after surface collision are consistent with the native quaternary structure of several protein systems studied, even for a large chaperone protein, GroEL, that approaches megadalton mass. The unique and meaningful data generated from surface induced dissociation (SID) have been attributed to the fast and energetic activation process upon collision with a massive target, the surface. In this Account, we summarize our SID studies of protein complexes, with emphasis on the more recent work on the combination of ion mobility (IM) with SID. IM has gained popularity over the years not only as a gas-phase separation technique but also as a technique with the ability to measure the size and shape of the proteins in the gas phase. Incorporation of IM before SID allows different conformations of a protein to be separated and examined individually by SID for structural details. When IM is after SID, the cross sections of the SID products can be measured, providing insight on the dissociation pathways, which may mimic disassembly pathways. Furthermore, the separation by IM greatly reduces the peak overlapping (same m/z) and coalescence (merging) of SID products, improving the resolving power of the method. While there are still many unanswered questions on the fundamental properties of gas-phase proteins and a need for further research, our work has shown that SID can be a complementary gas-phase tool providing useful information for studying quaternary structures of noncovalent protein complexes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Hall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267
Allosteric mechanisms can be distinguished using structural mass spectrometry
Dyachenko, A., Gruber, R., Shimon, L., Horovitz, A., & Sharon, M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1302395110 · Cited by 144
Zhou, M., Dagan, S., & Wysocki, V. H. (2013) · The Analyst · doi:10.1039/c2an36525a · Cited by 92
Self-citationBlackwell, A. E., Dodds, E. D., Bandarian, V., & Wysocki, V. H. (2011) · Analytical Chemistry · doi:10.1021/ac200452b · Cited by 84
Self-citation
Cited by
Experimental Binding Energies in Supramolecular Complexes
Biedermann, F., & Schneider, H.-J. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00583 · Cited by 554
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules
Brodbelt, J. S., Morrison, L. J., & Santos, I. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00440 · Cited by 295
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“For more information on alternative approaches, please refer to Bogdanov and Smith (2005); Brodbelt (2014); Zhou and Wysocki (2014); Zubarev (2004).”
Metadata
- Authors
- Zhou, M., & Wysocki, V. H.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-02-13
- Volume
- 47
- Issue
- 4
- Pages
- 1010-1018
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2315485810
- Cited by
- 136
- References
- 7
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.