The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fast Electrochemistry of Conductive Polymer Nanotubes: Synthesis, Mechanism, and Application
Abstract
Conductive polymers exhibit several interesting and important properties, such as metallic conductivity and reversible convertibility between redox states. When the redox states have very different electrochemical and electronic properties, their interconversion gives rise to changes in the polymers' conformations, doping levels, conductivities, and colors, useful attributes if they are to be applied in displays, energy storage devices, actuators, and sensors. Unfortunately, the rate of interconversion is usually slow, at best on the order a few hundred milliseconds, because of the slow transport of counterions into the polymer layer to balance charge. This phenomenon is one of the greatest obstacles toward building rapidly responsive electrochemical devices featuring conductive polymers. One approach to enhancing the switching speed is decreasing the diffusion distance for the counterions in the polymer. We have found that nanotubular structures are good candidates for realizing rapid switching between redox states because the counterions can be readily doped throughout the thin nanotube walls. Although the synthesis of conductive polymer nanotubes can be performed using electrochemical template synthesis, the synthetic techniques and underlying mechanisms controlling the nanotube morphologies are currently not well established. We begin this Account by discussing the mechanisms for controlling the structures from hollow nanotubes to solid nanowires. The applied potential, monomer concentration, and base electrode shape all play important roles in determining the nanotubes' morphologies. A mechanism based on the rates of monomer diffusion and reaction allows the synthesis of nanotubes at high oxidation potentials; a mechanism dictated by the base-electrode shape dominates at very low oxidation potentials. The structures of the resulting conductive polymer nanotubes, such as those of poly(3,4-ethylenedioxythiophene) (PEDOT) and polypyrrole, can be characterized using scanning electron microscopy and transmission electron microscopy. We also discuss these materials in terms of their prospective use in nanotube-based electrochemical devices. For example, we describe an electrochromic device incorporating PEDOT nanotubes that exhibits an ultrafast color switching rate (<10 ms) and strong coloration. In addition, we report a supercapacitor based on PEDOT nanotubes that can provide more than 80% of its own energy density, even at power demands as high as 25 kW/kg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conjugated Polymer-Based Organic Solar Cells
Günes, S., Neugebauer, H., & Sariciftci, N. S. (2007) · Chemical Reviews · doi:10.1021/cr050149z · Cited by 6,279
Cited by
Electrochemistry of Conducting Polymers—Persistent Models and New Concepts
Heinze, J., Frontana-Uribe, B. A., & Ludwigs, S. (2010) · Chemical Reviews · doi:10.1021/cr900226k · Cited by 1,258
Additive Manufacturing of Batteries
Pang, Y., Cao, Y., Chu, Y., Liu, M., Snyder, K., MacKenzie, D., & Cao, C. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906244 · Cited by 298
Metadata
- Authors
- Cho, S. I., & Lee, S. B.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-05-28
- Volume
- 41
- Issue
- 6
- Pages
- 699-707
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2085803215
- Cited by
- 410
- References
- 1
- FWCI
- 30.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.