Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 647

The DOI matches its Crossref record.

Chemosensors for Pyrophosphate

Kim, Sook Kyung, Lee, Dong Hoon, Hong, Jong-In, Yoon, Juyoung·2009·Accounts of Chemical Research

Abstract

The selective detection of the anion pyrophosphate (PPi) is a major research focus. PPi is a biologically important target because it is the product of ATP hydrolysis under cellular conditions, and because it is involved in DNA replication catalyzed by DNA polymerase, its detection is being investigated as a real-time DNA sequencing method. In addition, within the past decade, the ability to detect PPi has become important in cancer research. In general, the sensing of anions in aqueous solution requires a strong affinity for anions in water as well as the ability to convert anion recognition into a fluorescent or colorimetric signal. Among the variety of methods for detecting PPi, fluorescent chemosensors and colorimetric sensors for PPi have attracted considerable attention during the past 10 years. Compared with the recognition of metal ions, it is much more challenging to selectively recognize anions in an aqueous system due to the strong hydration effects of anions. Consequently, the design of PPi sensors requires the following: an understanding of the molecular recognition between PPi and the binding sites, the desired solubility in aqueous solutions, the communicating and signaling mechanism, and most importantly, selectivity for PPi over other anions such as AMP and ADP, and particularly phosphate and ATP. This Account classifies chemosensors for PPi according to topological and structural characteristics. Types of chemosensors investigated and reported in this study include those that contain metal ion complexes, metal complexes combined with excimers, those that function with a displacement approach, and those based on hydrogen-bonding interaction. Thus far, the utilization of a metal ion complex as a binding site for PPi has been the most successful strategy. The strong binding affinity between metal ions and PPi allows the detection of PPi in a 100% aqueous solution. We have demonstrated that carefully designed receptors can distinguish between PPi and ATP based on their different total anionic charge densities. We have also demonstrated that a PPi metal ion complex sensor has a bioanalytical application. This sensor can be used in a simple and quick, one-step, homogeneous phase detection method in order to confirm DNA amplification after polymerase chain reaction (PCR).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ar800003f

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kim, S. K., Lee, D. H., Hong, J.-I., & Yoon, J.
Venue
Accounts of Chemical Research
Published
2008-09-18
Volume
42
Issue
1
Pages
23-31
ISSN
  • 0001-4842 (ISSN-L)
  • 1520-4898
OpenAlex
W1990412045
Cited by
647
References
0
FWCI
19.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.