The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Phosphorescent chemosensors based on heavy-metal complexes
Abstract
Recently, the use of phosphorescent heavy-metal complexes as chemosensors has attracted increasing interest due to their advantageous photophysical properties. This critical review focuses on the design principles and the recent development of phosphorescent chemosensors for metal cations, anions, pH, oxygen, volatile organic compounds and biomolecules based on some heavy-metal complexes (such as Pt(II)-, Ru(II)-, Re(I)-, Ir(III)-, Cu(I)-, Au(I)- and Os(II)-based complexes), in which the variation in phosphorescence signals induced by the interaction between heavy-metal complexes and analytes is utilized (217 references).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pearson, R. G. (1963) · Journal of the American Chemical Society · doi:10.1021/ja00905a001 · Cited by 10,475
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Stadler, N., Lindner, R. A., & Davies, M. J. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000124892.90999.cb · Cited by 310
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Triplet photosensitizers: from molecular design to applications
Zhao, J., Wu, W., Sun, J., & Guo, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35531d · Cited by 1,579
You, Y., & Nam, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35171d · Cited by 668
Hsu, C.-W., Lin, C.-C., Chung, M.-W., Chi, Y., Lee, G.-H., Chou, P.-T., Chang, C.-H., & Chen, P.-Y. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2026568 · Cited by 365
Luminescent Metal–Organic Framework Films As Highly Sensitive and Fast-Response Oxygen Sensors
Dou, Z., Yu, J., Cui, Y., Yang, Y., Wang, Z., Yang, D., & Qian, G. (2014) · Journal of the American Chemical Society · doi:10.1021/ja411224j · Cited by 361
Metadata
- Authors
- Zhao, Q., Li, F., & Huang, C.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 8
- Pages
- 3007
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2131721476
- Cited by
- 1,249
- References
- 4
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phosphorescent chemosensors based on heavy-metal complexes. https://app.cochat.ai/papers/10.1039/b915340c
- The paper
- Zhao, Q., Li, F., & Huang, C. (2010). Phosphorescent chemosensors based on heavy-metal complexes. Chemical Society Reviews. https://doi.org/10.1039/b915340c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.