Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 321

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Bioresponsive, Cell-Penetrating, and Multimeric MR Contrast Agents

Open access
Major, Jody L., Meade, Thomas J.·2009·Accounts of Chemical Research

Abstract

Magnetic resonance imaging (MRI) has become increasingly popular in experimental molecular imaging and clinical radiology because it is non-invasive and capable of producing three-dimensional representations of opaque organisms with high spatial and temporal resolution. Approximately 35% of all clinical MR scans utilize contrast media, however a primary limitation of MR imaging is the sensitivity of contrast agents that require high concentrations (0.1-0.6 mM). A number of strategies have been employed to amplify the observed in vivo signal of MR contrast agents. Approaches include attachment of Gd(III) chelates to polymers, proteins and particles, encapsulation into micelles and caged structures, and targeting to receptors. While each of these approaches has yielded significant increases in the relaxivity of MR contrast agents (and therefore sensitivity), all of these classes of complexes possess intrinsic background signal and function solely as anatomical reporters. In order to reduce the background signal and simultaneously create probes that are modulated by biochemical processes, caged complexes were designed to coordinatively saturate the paramagnetic ion. Coupled with amplification strategies, these agents represent a means to selectively modulate the observed MR signal and function as in vivo biochemical reporters. For example, to create an in vivo MR assay of enzymatic activities and secondary messengers, agents have been designed and synthesized with removable protection groups that largely prevent access of water to a paramagnetic center. By limiting the access of bulk water (q-modulation) the unprocessed agent is designed to be an ineffective contrast agent, and hence serves as a reliable marker for regions of enzyme activity or the presence of secondary messengers. Further, we have focused on designing multimodal contrast agents that are simultaneously detectable by more than one imaging technique. For example, attaching an optical probe to a MR contrast agent provides the means to detect the probe in a whole animal and subsequently validate the results by histological methods. Finally, we describe strategies for signal amplification, and cell delivery vehicles attached to imaging probes for in vivo long-term fate mapping experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ar800245h

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 321

Metadata

Authors
Major, J. L., & Meade, T. J.
Venue
Accounts of Chemical Research
Published
2009-06-19
Volume
42
Issue
7
Pages
893-903
ISSN
  • 0001-4842 (ISSN-L)
  • 1520-4898
OpenAlex
W1992834159
Cited by
321
References
39
FWCI
14.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioresponsive, Cell-Penetrating, and Multimeric MR Contrast Agents. https://app.cochat.ai/papers/10.1021/ar800245h
The paper
Major, J. L., & Meade, T. J. (2009). Bioresponsive, Cell-Penetrating, and Multimeric MR Contrast Agents. Accounts of Chemical Research. https://doi.org/10.1021/ar800245h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.