The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Bioresponsive, Cell-Penetrating, and Multimeric MR Contrast Agents
Open accessAbstract
Magnetic resonance imaging (MRI) has become increasingly popular in experimental molecular imaging and clinical radiology because it is non-invasive and capable of producing three-dimensional representations of opaque organisms with high spatial and temporal resolution. Approximately 35% of all clinical MR scans utilize contrast media, however a primary limitation of MR imaging is the sensitivity of contrast agents that require high concentrations (0.1-0.6 mM). A number of strategies have been employed to amplify the observed in vivo signal of MR contrast agents. Approaches include attachment of Gd(III) chelates to polymers, proteins and particles, encapsulation into micelles and caged structures, and targeting to receptors. While each of these approaches has yielded significant increases in the relaxivity of MR contrast agents (and therefore sensitivity), all of these classes of complexes possess intrinsic background signal and function solely as anatomical reporters. In order to reduce the background signal and simultaneously create probes that are modulated by biochemical processes, caged complexes were designed to coordinatively saturate the paramagnetic ion. Coupled with amplification strategies, these agents represent a means to selectively modulate the observed MR signal and function as in vivo biochemical reporters. For example, to create an in vivo MR assay of enzymatic activities and secondary messengers, agents have been designed and synthesized with removable protection groups that largely prevent access of water to a paramagnetic center. By limiting the access of bulk water (q-modulation) the unprocessed agent is designed to be an ineffective contrast agent, and hence serves as a reliable marker for regions of enzyme activity or the presence of secondary messengers. Further, we have focused on designing multimodal contrast agents that are simultaneously detectable by more than one imaging technique. For example, attaching an optical probe to a MR contrast agent provides the means to detect the probe in a whole animal and subsequently validate the results by histological methods. Finally, we describe strategies for signal amplification, and cell delivery vehicles attached to imaging probes for in vivo long-term fate mapping experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Relaxation Processes in a System of Two Spins
Solomon, I. (1955) · Physical Review · doi:10.1103/physrev.99.559 · Cited by 3,278
The biochemical basis of zinc physiology
Vallee, B. L., & Falchuk, K. H. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.79 · Cited by 2,990
The Chemistry of Contrast Agents in Medical Magnetic Resonance Imaging
(2013) · Wiley eBooks · doi:10.1002/9781118503652 · Cited by 1,468
Strategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Proton Relaxation Times in Paramagnetic Solutions. Effects of Electron Spin Relaxation
Bloembergen, N., & Morgan, L. O. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731684 · Cited by 1,348
Peptide-amphiphile nanofibers: A versatile scaffold for the preparation of self-assembling materials
Hartgerink, J. D., Beniash, E., & Stupp, S. I. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.072699999 · Cited by 1,240
In vivo visualization of gene expression using magnetic resonance imaging
Louie, A. Y., Hüber, M. M., Ahrens, E. T., Rothbächer, U., Moats, R., Jacobs, R. E., Fraser, S. E., & Meade, T. J. (2000) · Nature Biotechnology · doi:10.1038/73780 · Cited by 1,141
Self-citationImportance of Zinc in the Central Nervous System: The Zinc-Containing Neuron
Frederickson, C. J., Suh, S. W., Silva, D., Frederickson, C. J., & Thompson, R. B. (2000) · The Journal of Nutrition · doi:10.1093/jn/130.5.1471s · Cited by 866
Zinc: a multipurpose trace element
Stefanidou, M., Maravelias, C., Dona, A., & Spiliopoulou, C. (2006) · Archives of Toxicology · doi:10.1007/s00204-005-0009-5 · Cited by 473
Movement of zinc and its functional significance in the brain
Takeda, A. (2000) · Brain Research Reviews · doi:10.1016/s0165-0173(00)00044-8 · Cited by 417
Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973.
Pc, L. (1989) · PubMed · Cited by 391
A “Smart” Magnetic Resonance Imaging Agent That Reports on Specific Enzymatic Activity
Moats, R. A., Fraser, S. E., & Meade, T. J. (1997) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199707261 · Cited by 330
Self-citationNext Generation, High Relaxivity Gadolinium MRI Agents
Raymond, K. N., & Pierre, V. C. (2005) · Bioconjugate Chemistry · doi:10.1021/bc049817y · Cited by 328
Zhang, X.-A., Lovejoy, K. S., Jasanoff, A., & Lippard, S. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702393104 · Cited by 294
A Novel pH‐Sensitive MRI Contrast Agent
Zhang, S., Wu, K., & Sherry, A. D. (1999) · Angewandte Chemie International Edition · Cited by 259
Self-Assembled Peptide Amphiphile Nanofibers Conjugated to MRI Contrast Agents
Bull, S. R., Guler, M. O., Bras, R. E., Meade, T. J., & Stupp, S. I. (2005) · Nano Letters · doi:10.1021/nl0484898 · Cited by 237
Self-citationMultimodal MRI contrast agents
Frullano, L., & Meade, T. J. (2007) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-007-0265-3 · Cited by 229
Self-citationMagnetic resonance molecular imaging of the HER-2/neu receptor.
Artemov, D., Mori, N., Ravi, R. K., & Bhujwalla, Z. M. (2003) · PubMed · Cited by 217
Fluorescently Detectable Magnetic Resonance Imaging Agents
Hüber, M. M., Staubli, A. B., Kustedjo, K., Gray, M. H. B., Shih, J., Fraser, S. E., Jacobs, R. E., & Meade, T. J. (1998) · Bioconjugate Chemistry · doi:10.1021/bc970153k · Cited by 204
Self-citationPan, D., Caruthers, S. D., Hu, G., Senpan, A., Scott, M. J., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2008) · Journal of the American Chemical Society · doi:10.1021/ja801482d · Cited by 186
The synthesis and in vitro testing of a zinc-activated MRI contrast agent
Major, J. L., Parigi, G., Luchinat, C., & Meade, T. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706247104 · Cited by 184
Self-citationSynthesis of Multimeric MR Contrast Agents for Cellular Imaging
Song, Y., Kohlmeir, E. K., & Meade, T. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja0777990 · Cited by 182
Self-citationMRI Thermometry Based on PARACEST Agents
Zhang, S., Malloy, C. R., & Sherry, A. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053799t · Cited by 173
High Relaxivity Gadolinium Hydroxypyridonate−Viral Capsid Conjugates: Nanosized MRI Contrast Agents1
Datta, A., Hooker, J. M., Botta, M., Francis, M. B., Aime, S., & Raymond, K. N. (2008) · Journal of the American Chemical Society · doi:10.1021/ja0765363 · Cited by 172
Bhorade, R., Weissleder, R., Nakakoshi, T., Moore, A., & Tung, C.-H. (2000) · Bioconjugate Chemistry · doi:10.1021/bc990168d · Cited by 163
Mechanistic Studies of a Calcium-Dependent MRI Contrast Agent
Li, W.-H., Parigi, G., Fragai, M., Luchinat, C., & Meade, T. J. (2002) · Inorganic Chemistry · doi:10.1021/ic0200390 · Cited by 159
Self-citationAn overview of responsive MRI contrast agents for molecular imaging
Yoo, B. (2007) · Frontiers in bioscience · doi:10.2741/2796 · Cited by 142
Magnetic Resonance Imaging of Self-Assembled Biomaterial Scaffolds
Bull, S. R., Guler, M. O., Bras, R. E., et al. (2005) · Bioconjugate Chemistry · doi:10.1021/bc050153h · Cited by 94
Membrane permeability commonly shared among arginine‐rich peptides
Futaki, S., Goto, S., & Sugiura, Y. (2003) · Journal of Molecular Recognition · doi:10.1002/jmr.635 · Cited by 84
Synthesis and visualization of a membrane-permeable MRI contrast agent
Allen, M. J., & Meade, T. J. (2003) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-003-0475-2 · Cited by 71
Self-citationMishra, A., Fousková, P., Angelovski, G., Balogh, E., Mishra, A. K., Logothetis, N. K., & Tóth, É. (2008) · Inorganic Chemistry · doi:10.1021/ic7017456 · Cited by 70
Dhingra, K., Fousková, P., Angelovski, G., Maier, M. E., Logothetis, N. K., & Tóth, É. (2007) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-007-0296-9 · Cited by 68
Gustafsson, B. I., Youens, S., & Louie, A. Y. (2006) · Bioconjugate Chemistry · doi:10.1021/bc060018k · Cited by 43
Rational Design, Synthesis, and Biological Evaluation of Progesterone-Modified MRI Contrast Agents
Lee, J., Burdette, J. E., MacRenaris, K. W., Mustafi, D., Woodruff, T. K., & Meade, T. J. (2007) · Chemistry & Biology · doi:10.1016/j.chembiol.2007.06.006 · Cited by 39
Self-citationQuantitative Imaging of Cell-Permeable Magnetic Resonance Contrast Agents Using X-Ray Fluorescence
Endres, P. J., MacRenaris, K. W., Vogt, S., Allen, M. J., & Meade, T. J. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00026 · Cited by 38
Self-citationIs zinc the link between compromises of brain perfusion (excitotoxicity) and Alzheimer's disease?
Frederickson, C. J., Cuajungco, M. P., & Frederickson, C. J. (2005) · Journal of Alzheimer s Disease · doi:10.3233/jad-2005-8208 · Cited by 28
Sun, P. Z., Schoening, Z. B., & Jasanoff, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10405 · Cited by 21
Cited by
Lanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Self-citationZhao, Z., Zhou, Z., Bao, J., Wang, Z., Hu, J., Chi, X., Ni, K., Wang, R., Chen, X., Chen, Z., et al. (2013) · Nature Communications · doi:10.1038/ncomms3266 · Cited by 477
Que, E. L., & Chang, C. J. (2010) · Chem. Soc. Rev. · doi:10.1039/b914348n · Cited by 263
Hu, F., Jia, Q., Li, Y., & Gao, M. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/24/245604 · Cited by 147
Metadata
- Authors
- Major, J. L., & Meade, T. J.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-19
- Volume
- 42
- Issue
- 7
- Pages
- 893-903
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W1992834159
- Cited by
- 321
- References
- 39
- FWCI
- 14.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.