The DOI matches its Crossref record.
In Vivo Imaging of Activated Endothelium Using an Anti-VCAM-1 Magnetooptical Probe
Abstract
It has been suggested that vascular cell adhesion molecule-1 (VCAM-1) could serve as an early marker for inflammation of the endothelium. The ability to noninvasively image VCAM-1 could thus be a useful tool to diagnose a number of inflammatory diseases at early stages. Here we demonstrate that magnetooptical nanoparticles conjugated to anti-VCAM-1 antibodies can be used to specifically detect VCAM-1 expression on endothelial cells in culture and in vivo. Elevated VCAM-1 expression was detected on cultured murine heart endothelial cells by both fluorescence and magnetic resonance, while only basal expression levels were detected on murine dermal endothelial cells. Intravital microscopy of a murine inflammatory model injected with the VCAM-1 targeted nanoparticles revealed specific labeling of the activated endothelium, with labeling kinetics yielding a maximum vessel wall signal 6 h after injection. In contrast, nontargeted nanoparticles did not exhibit any specific labeling of the endothelium. These studies suggest that the developed nanoparticle would be useful for MR and optical detection of activated endothelium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Mahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Multifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Self-citationSuperparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Self-citation
Metadata
- Authors
- Tsourkas, A., Shinde-Patil, V. R., Kelly, K. A., Patel, P., Wolley, A., Allport, J. R., & Weissleder, R.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-04-28
- Volume
- 16
- Issue
- 3
- Pages
- 576-581
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W1977793874
- Cited by
- 171
- References
- 0
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Imaging of Activated Endothelium Using an Anti-VCAM-1 Magnetooptical Probe. https://app.cochat.ai/papers/10.1021/bc050002e
- The paper
- Tsourkas, A., Shinde-Patil, V. R., Kelly, K. A., Patel, P., Wolley, A., Allport, J. R., & Weissleder, R. (2005). In Vivo Imaging of Activated Endothelium Using an Anti-VCAM-1 Magnetooptical Probe. Bioconjugate Chemistry. https://doi.org/10.1021/bc050002e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.