The DOI matches its Crossref record.
Fluorescent Nanoparticles for Multiplexed Bacteria Monitoring
Abstract
Rapid, sensitive, and selective detection of pathogenic bacteria is extremely important for proper containment, diagnosis, and treatment of diseases like foodborne illness, sepsis, and bioterrorism. Most current bacterial detection methods are time-consuming and laborious and can detect only one bacterial pathogen at a time. We have developed a method for sensitive, multiplexed monitoring of bacterial pathogens within 30 min using multicolored FRET (fluorescence resonance energy transfer) silica NPs (nanoparticles). By varying the ratio of three tandem dyes coencapsulated into the NPs, we have synthesized NPs that emit unique colors upon excitation with a single wavelength. When these NPs were conjugated to monoclonal antibodies specific for the pathogenic bacteria species Escherichia coli, Salmonella typhimurium, and Staphylococcus aureus, and then incubated with small concentrations of the bacteria, simultaneous and sensitive detection of the multiple bacterial targets was achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Croissant, J. G., Fatieiev, Y., Almalik, A., & Khashab, N. M. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700831 · Cited by 594
Impact of protein pre-coating on the protein corona composition and nanoparticle cellular uptake
Mirshafiee, V., Kim, R., Park, S., Mahmoudi, M., & Kraft, M. L. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.10.019 · Cited by 316
Nanobioimaging and sensing of infectious diseases
Tallury, P., Malhotra, A., Byrne, L. M., & Santra, S. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.014 · Cited by 301
Inorganic nanoparticles engineered to attack bacteria
Miller, K. P., Wang, L., Benicewicz, B. C., & Decho, A. W. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00041f · Cited by 290
Self-citationAmine-Functionalized Magnetic Nanoparticles for Rapid Capture and Removal of Bacterial Pathogens
Huang, Y.-F., Wang, Y.-F., & Yan, X.-P. (2010) · Environmental Science & Technology · doi:10.1021/es102285n · Cited by 279
Antimicrobial Activity of Silver Nanocrystals Encapsulated in Mesoporous Silica Nanoparticles
Liong, M., France, B., Bradley, K. A., & Zink, J. I. (2009) · Advanced Materials · doi:10.1002/adma.200802646 · Cited by 262
Nanotools for Sepsis Diagnosis and Treatment
Papafilippou, L., Claxton, A., Dark, P., Kostarelos, K., & Hadjidemetriou, M. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001378 · Cited by 118
Metadata
- Authors
- Wang, L., Zhao, W., O'Donoghu, M. B., & Tan, W.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-03-01
- Volume
- 18
- Issue
- 2
- Pages
- 297-301
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2079352334
- Cited by
- 184
- References
- 0
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.