The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
A New, Simple Method for Linking of Antibodies to Atomic Force Microscopy Tips
Abstract
Functionalization of atomic force microscope (AFM) tips with bioligands converts them into monomolecular biosensors which can detect complementary receptor molecules on the sample surface. Flexible PEG tethers are preferred because the bioligand can freely reorient and locally palpate the sample surface while the AFM tip is moved along. In a well-established coupling scheme [Hinterdorfer et al. (1996) Proc. Natl. Acad. Sci. U.S.A. 93, 3477-3481], a heterobifunctional PEG linker is used to tether thiol-containing bioligands to amino-functionalized AFM tips. Since antibodies contain no free thiol residues, prederivatization with N-succinimidyl 3-(acetylthio)propionate (SATP) is needed which causes a relatively high demand for antibody. The present study offers a convenient alternative with minimal protein consumption (e.g., 5 microg of protein in 50 microL of buffer) and no prederivatization, using a new heterobifunctional cross-linker that has two different amino-reactive functions. One end is an activated carboxyl (N-hydroxysuccinimide ester) which is much faster to react with the amino groups of the tips than the benzaldehyde function on its other end. The reactivity of the latter is sufficient, however, to covalently bind lysine residues of proteins via Schiff base formation. The method has been critically examined, using biotinylated IgG as bioligand on the tip and mica-bound avidin as complementary receptor. These experiments were well reproduced on amino-functionalized silicon nitride chips where the number of specifically bound IgG molecules (approximately 2000 per microm2) was estimated from the amount of specifically bound ExtrAvidin-peroxidase conjugate. For a bioscientific application, human rhinovirus particles were tethered to the tip, very-low-density lipoprotein receptor fragments were tethered to mica, and the specific interaction was studied by force microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic strength of molecular adhesion bonds
Evans, E., & Ritchie, K. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78802-7 · Cited by 2,549
Intermolecular forces in biology
Leckband, D., & Israelachvili, J. (2001) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583501003687 · Cited by 692
Mapping interaction forces with the atomic force microscope
Radmacher, M., Cleveland, J. P., Fritz, M., Hansma, H. G., & Hansma, P. K. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)81011-2 · Cited by 332
Simple test system for single molecule recognition force microscopy
Riener, C. K., Stroh, C. M., Ebner, A., Klampfl, C., Gall, A. A., Romanin, C., Lyubchenko, Y. L., Hinterdorfer, P., & Gruber, H. J. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)01373-9 · Cited by 200
Self-citationMolecular Recognition Imaging and Force Spectroscopy of Single Biomolecules
Kienberger, F., Ebner, A., Gruber, H. J., & Hinterdorfer, P. (2006) · Accounts of Chemical Research · doi:10.1021/ar050084m · Cited by 191
Self-citationSimultaneous Topography and Recognition Imaging Using Force Microscopy
Stroh, C. M., Ebner, A., Geretschläger, M., Freudenthaler, G., Kienberger, F., Kamruzzahan, A. S. M., Smith-Gill, S. J., Gruber, H. J., & Hinterdorfer, P. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.043331 · Cited by 164
Self-citationData analysis of interaction forces measured with the atomic force microscope
Baumgärtner, W., Hinterdorfer, P., & Schindler, H. (2000) · Ultramicroscopy · doi:10.1016/s0304-3991(99)00154-0 · Cited by 156
Self-citationHewat, E. A., Neumann, E., Conway, J. F., Moser, R., Ronacher, B., Marlovits, T. C., & Blaas, D. (2000) · The EMBO Journal · doi:10.1093/emboj/19.23.6317 · Cited by 144
Self-citationForce Spectroscopy of the Double-Tethered Concanavalin-A Mannose Bond
Ratto, T. V., Langry, K. C., Rudd, R. E., Balhorn, R., Allen, M. J., & McElfresh, M. W. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74299-x · Cited by 118
Scheuring, S., Müller, D. J., Ringler, P., Heymann, J. B., & Engel, A. H. (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00434.x · Cited by 102
Cited by
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
Force probing surfaces of living cells to molecular resolution
Müller, D. J., Helenius, J., Alsteens, D., & Dufrêne, Y. F. (2009) · Nature Chemical Biology · doi:10.1038/nchembio.181 · Cited by 480
Applications of biosensing atomic force microscopy in monitoring drug and nanoparticle delivery
Lamprecht, C., Hinterdorfer, P., & Ebner, A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.917078 · Cited by 46
Beaussart, A., El-Kirat-Chatel, S., Fontaine, T., Latgé, J.-P., & Dufrêne, Y. F. (2015) · Nanoscale · doi:10.1039/c5nr04399a · Cited by 34
Metadata
- Authors
- Ebner, A., Wildling, L., Kamruzzahan, A. S. M., Rankl, C., Wruss, J., Hahn, C. D., Hölzl, M., Zhu, R., Kienberger, F., Blaas, D., Hinterdorfer, P., & Gruber, H. J.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-05-22
- Volume
- 18
- Issue
- 4
- Pages
- 1176-1184
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2005545805
- Cited by
- 264
- References
- 12
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.