The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Extracellular Barriers to in Vivo PEI and PEGylated PEI Polyplex-Mediated Gene Delivery to the Liver
Abstract
Polyplex-mediated gene therapy is a promising alternative to viral gene therapy. One challenge to these synthetic carriers is reduced transfection efficiencies in vivo compared to those achieved in vitro. Many of the intracellular barriers to gene delivery have been elucidated, but similar quantification of extracellular barriers to gene delivery remains a need. In this study, the unpackaging of polyplexes by serum proteins, soluble glycosaminoglycans, and an extracellular matrix extract was demonstrated by a YOYO-1 fluorescence quenching assay. Additionally, exposing polyplexes to serum or proteoglycans before in vitro transfection caused decreased cellular uptake of DNA. Lastly, PEI polyplexes and PEGylated PEI polyplexes were injected into the portal vein of mice, and the intrahepatic distributions of labeled DNA and polymer were assessed by confocal microscopy. PEI polyplexes delivered DNA to the liver, but extensive vector unpackaging was observed, with PEI primarily colocalized with the extracellular matrix. PEGylated polyplexes mediated less DNA delivery to the liver, possibly due to premature vector unpackaging in the blood. Through this work, both the blood and the extracellular matrix have been determined to be significant extracellular barriers to polyplex-mediated in vivo gene delivery to the liver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and development of polymers for gene delivery
Pack, D. W., Hoffman, A. S., Pun, S., & Stayton, P. S. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1775 · Cited by 2,568
Self-citationOgris, M., Brunner, S., Schüller, S., Kircheis, R., & Wagner, E. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300900 · Cited by 1,178
Dash, P. R., Read, M. L., Barrett, L. B., Wolfert, M. A., & Seymour, L. W. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300843 · Cited by 386
Cited by
Block copolymer micelles in nanomedicine applications
Cabral, H., Miyata, K., Osada, K., & Kataoka, K. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00199 · Cited by 1,309
Nucleic Acid Therapeutics Using Polyplexes: A Journey of 50 Years (and Beyond)
Lächelt, U., & Wagner, E. (2015) · Chemical Reviews · doi:10.1021/cr5006793 · Cited by 600
Polymeric Delivery of Therapeutic Nucleic Acids
Kumar, R., Santa Chalarca, C. F., Bockman, M. R., Bruggen, C. V., Grimme, C. J., Dalal, R. J., Hanson, M. G., Hexum, J. K., & Reineke, T. M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00997 · Cited by 365
Highly PEGylated DNA Nanoparticles Provide Uniform and Widespread Gene Transfer in the Brain
Mastorakos, P., Zhang, C., Berry, S., Oh, Y., Lee, S., Eberhart, C. G., Woodworth, G. F., Suk, J. S., & Hanes, J. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400800 · Cited by 80
Metadata
- Authors
- Burke, R. S., & Pun, S. H.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-23
- Volume
- 19
- Issue
- 3
- Pages
- 693-704
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2024111722
- Cited by
- 221
- References
- 3
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.