Hemolytic Activity of pH-Responsive Polymer-Streptavidin Bioconjugates
The DOI matches its Crossref record.
Abstract
Drug delivery systems that increase the rate and/or quantity of drug release to the cytoplasm are needed to enhance cytosolic delivery and to circumvent nonproductive cell trafficking routes. We have previously demonstrated that poly(2-ethylacrylic acid) (PEAAc) has pH-dependent hemolytic properties, and more recently, we have found that poly(2-propylacrylic acid) (PPAAc) displays even greater pH-responsive hemolytic activity than PEAAc at the acidic pHs of the early endosome. Thus, these polymers could potentially serve as endosomal releasing agents in immunotoxin therapies. In this paper, we have investigated whether the pH-dependent membrane disruptive activity of PPAAc is retained after binding to a protein. We did this by measuring the hemolytic activity of PPAAc-streptavidin model complexes with different protein to polymer stoichiometries. Biotin was conjugated to amine-terminated PPAAc, which was subsequently bound to streptavidin by biotin complexation. The ability of these samples to disrupt red blood cell membranes was investigated for a range of polymer concentrations, a range of pH values, and two polymer-to-streptavidin ratios of 3:1 and 1:1. The results demonstrate that (a) the PPAAc-streptavidin complex retains the ability to lyse the RBC lipid bilayers at low pHs, such as those existing in endosomes, and (b) the hemolytic ability of the PPAAc-streptavidin complex is similar to that of the free PPAAc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385
Carbon Nanotubes as Intracellular Protein Transporters: Generality and Biological Functionality
Kam, N. W. S., & Dai, H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja050062v · Cited by 1,047
Lessons from nature: stimuli-responsive polymers and their biomedical applications
Jeong, B., & Gutowska, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01962-5 · Cited by 856
Stimuli-responsive polymers: Biomedical applications and challenges for clinical translation
Hoffman, A. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.11.004 · Cited by 759
Self-citationSmart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Metadata
- Authors
- Lackey, C. A., Murthy, N., Press, O. W., Tirrell, D. A., Hoffman, A. S., & Stayton, P. S.
- Venue
- Bioconjugate Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-04-24
- Volume
- 10
- Issue
- 3
- Pages
- 401-405
- ISSN
- 1043-1802 (ISSN-L)
- 1520-4812
- OpenAlex
- W2062337731
- Cited by
- 125
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemolytic Activity of pH-Responsive Polymer-Streptavidin Bioconjugates. https://app.cochat.ai/papers/10.1021/bc980109k
- The paper
- Lackey, C. A., Murthy, N., Press, O. W., Tirrell, D. A., Hoffman, A. S., & Stayton, P. S. (1999). Hemolytic Activity of pH-Responsive Polymer-Streptavidin Bioconjugates. Bioconjugate Chemistry. https://doi.org/10.1021/bc980109k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.