Thermodynamic study of internal loops in oligoribonucleotides: symmetric loops are more stable than asymmetric loops
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Thermodynamic parameters for internal loops of unpaired adenosines in oligoribonucleotides have been measured by optical melting studies. Comparisons are made between helices containing symmetric and asymmetric loops. Asymmetric loops destabilize a helix more than symmetric loops. The differences in free energy between symmetric and asymmetric loops are roughly half the magnitude suggested from a study of parameters required to give accurate predictions of RNA secondary structure [Papanicolaou, C., Gouy, M., & Ninio, J. (1984) Nucleic Acids Res. 12, 31-44]. Circular dichroism spectra indicate no major structural difference between helices containing symmetric and asymmetric loops. The measured sequence dependence of internal loop stability is not consistent with approximations used in current algorithms for predicting RNA secondary structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved free-energy parameters for predictions of RNA duplex stability.
Freier, S. M., Kierzek, R., Jaeger, J. A., Sugimoto, N., Caruthers, M. H., Neilson, T., & Turner, D. H. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.24.9373 · Cited by 1,470
Self-citation
Cited by
Mathews, D. H., Sabina, J., Zuker, M., & Turner, D. H. (1999) · Journal of Molecular Biology · doi:10.1006/jmbi.1999.2700 · Cited by 3,795
“The table of 1 1 loops contains experimentally determined values from our lab (R.K. et al., unpublished results; Peritz et al., 1991).”
BackgroundSelf-citationMathews, D. H., Disney, M. D., Childs, J. L., Schroeder, S. J., Zuker, M., & Turner, D. H. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401799101 · Cited by 1,622
Self-citationXia, T., SantaLucia, J., Burkard, M. E., Kierzek, R., Schroeder, S. J., Jiao, X., Cox, C., & Turner, D. H. (1998) · Biochemistry · doi:10.1021/bi9809425 · Cited by 1,140
Self-citationThermodynamic parameters to predict stability of RNA/DNA hybrid duplexes
Sugimoto, N., Nakano, S.-I., Katoh, M., Matsumura, A., Nakamuta, H., Ohmichi, T., Yoneyama, M., & Sasaki, M. (1995) · Biochemistry · doi:10.1021/bi00035a029 · Cited by 697
Self-citationWalter, A. E., Turner, D. H., Kim, J., Lyttle, M. H., Müller, P., Mathews, D. H., & Zuker, M. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.20.9218 · Cited by 466
Self-citation
Metadata
- Authors
- Peritz, A. E., Kierzek, R., Sugimoto, N., & Turner, D. H.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1991-07-02
- Volume
- 30
- Issue
- 26
- Pages
- 6428-6436
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2062562045
- Cited by
- 85
- References
- 1
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.