The DOI matches its Crossref record.
Spectra, membrane binding, and potentiometric responses of new charge shift probes
Abstract
The properties of a series of new potentiometric membrane probes have been explored. The probes all contain an (aminostyryl)pyridinium chromophore or a more highly conjugated analogue. The spectral properties of the dyes are discussed in terms of the excitation-induced charge shift from the pyridine to the aniline; this charge shift also provides the basis for the voltage dependence of the spectra according to an electrochromic mechanism. The spectral responses to a membrane potential on a hemispherical bilayer have been obtained and, grossly, are quite similar for all probes tested. The more subtle variations from dye to dye can be partially rationalized by consideration of binding parameters, the depth within the membrane, and structural factors. The most potential sensitive dye in this collection has been designated di-4-ANEPPS and has a 6-amino-2-naphthyl group in place of the p-anilino on the parent chromophore. Both the relative fluorescence emission and excitation responses have maxima of 8% per 100 mV, and these two spectra display a striking symmetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grabowski, Z. R., Rotkiewicz, K., & Rettig, W. (2003) · Chemical Reviews · doi:10.1021/cr940745l · Cited by 3,714
Cevc, G. (1990) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(90)90015-5 · Cited by 522
Optically monitoring voltage in neurons by photo-induced electron transfer through molecular wires
Miller, E. W., Lin, J. Y., Frady, E. P., Steinbach, P. A., Kristan, W. B., & Tsien, R. Y. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1120694109 · Cited by 323
Small-molecule fluorophores and fluorescent probes for bioimaging
Terai, T., & Nagano, T. (2013) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-013-1234-z · Cited by 301
Dual-wavelength ratiometric fluorescence measurement of the membrane dipole potential
Gross, E., Bedlack, R. S., & Loew, L. M. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80471-0 · Cited by 282
Self-citation
Metadata
- Authors
- Fluhler, E., Burnham, V. G., & Loew, L. M.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1985-10-01
- Volume
- 24
- Issue
- 21
- Pages
- 5749-5755
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2063637335
- Cited by
- 387
- References
- 0
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectra, membrane binding, and potentiometric responses of new charge shift probes. https://app.cochat.ai/papers/10.1021/bi00342a010
- The paper
- Fluhler, E., Burnham, V. G., & Loew, L. M. (1985). Spectra, membrane binding, and potentiometric responses of new charge shift probes. Biochemistry. https://doi.org/10.1021/bi00342a010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.