Isolation and properties of human neutrophil myeloperoxidase
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Human leukocyte myeloperoxidase has been purified to homogeneity by a three-step procedure which includes dialysis of a granule extract against low-salt buffer. Sephadex G-75 chromatography, and carboxymethylcellulose chromatography. The final product was homogeneous when examined by acid polyacrylamide gel electrophoresis and sedimentation equilibrium ultracentrifugation. The molecular weight determined by the latter procedure was 118000. With or without reduction of the protein by 2-mercaptoethanol, subunits were formed which migrated as a single band after sodium dodecyl sulfate gel electrophoresis. With reduction, the molecular weight of the apparently identical subunits was 59000, and 42000 without reduction. Other general properties of human leukocyte myeloperoxidase, including amino acid composition, amino terminal sequence analysis, and absorption spectra, are also reported. Myeloperoxidase, in the presence of hydrogen peroxide and chloride ion, and no other substrate, autoinactivates. After completion of the inactivation reaction, several oxidizable amino acids in the enzyme are modified, and the absorption peak at 430 nm disappears. The presence of a substrate of the myeloperoxidase system (alpha-1-proteinase inhibitor), or of high concentration of chloride ion, completely protects the enzyme from autoinactivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Immunologic Release of Constituents from Neutrophil Leukocytes
Henson, P. M. (1971) · The Journal of Immunology · doi:10.4049/jimmunol.107.6.1535 · Cited by 347
Cited by
Quantitative assay for acute intestinal inflammation based on myeloperoxidase activity
Krawisz, J. E., Sharon, P., & Stenson, W. F. (1984) · Gastroenterology · doi:10.1016/0016-5085(84)90202-6 · Cited by 1,758
Winterbourn, C. C. (1985) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(85)90120-5 · Cited by 462
Thiocyanate and chloride as competing substrates for myeloperoxidase
van DALEN, J. C., WHITEHOUSE, W. M., WINTERBOURN, C. C., & KETTLE, J. A. (1997) · Biochemical Journal · doi:10.1042/bj3270487 · Cited by 406
Heyworth, P. G., Cross, A. R., & Curnutte, J. T. (2003) · Current Opinion in Immunology · doi:10.1016/s0952-7915(03)00109-2 · Cited by 396
[53] Assays for the chlorination activity of myeloperoxidase
Kettle, A. J., & Winterbourn, C. C. (1994) · Methods in Enzymology · doi:10.1016/s0076-6879(94)33056-5 · Cited by 261
Metadata
- Authors
- Matheson, N. R., Wong, P. S., & Travis, J.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1981-01-01
- Volume
- 20
- Issue
- 2
- Pages
- 325-330
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W1987806264
- Cited by
- 149
- References
- 1
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.