Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 490

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Studies on the mechanism of membrane fusion: kinetics of calcium ion induced fusion of phosphatidylserine vesicles followed by a new assay for mixing of aqueous vesicle contents

Wilschut, Jan, Duzgunes, Nejat, Fraley, Robert, Papahadjopoulos, Demetrios·1980·Biochemistry

Abstract

We describe an assay for following the mixing of aqueous contents during fusion of phospholipid vesicles. Terbium is encapsulated as the Tb(citrate)3(6-) chelation complex in one population of vesicles, dipicolinic acid (DPA) in another. Vesicle fusion results in the formation of the fluorescent Tb(DPA)3(3-) chelation complex. The presence of EDTA (0.1 mM) and Ca2+ (greater than 1 mM) prevents the formation of the Tb/DPA complex in the external medium. We have studied the Ca2+-induced fusion of small or large unilamellar vesicles (SUV or LUV, respectively) composed of phosphatidylserine (PS). In addition, vesicle aggregation was monitored by light scattering, and release of vesicle contents was followed by carboxyfluorescein (CF) fluorescence enhancement. The addition of Ca2+ induced an immediate enhancement in Tb fluorescence with both SUV and LUV, which occurs on the same time scale as aggregation but much faster than the release of CF. The release of contents from LUV occurs with a considerable delay. It is estimated that the initial fusion of SUV is accompanied by 10% leakage of the internal volume per fusion event; in contrast, fusion of LUV is essentially nonleaky. Massive release of vesicle contents appears to be a secondary phenomenon related to the collapse of fused vesicles. The initial rate and the extent of Tb fluorescence enhancement are markedly dependent on the Ca2+ concentration. Threshold Ca2+ concentrations are 1.2 and 2.4 mM for SUV nd LUV, respectively. At saturating Ca2+ concentrations (greater than 10 mM), the rate of fusion of LUV is slightly lower than that of SUV at the same vesicle concentration. At any Ca2+ concentration, the rates of both SUV and LUV fusion are consistent with vesicle aggregation being rate limiting. When measured at a subsaturating Ca2+ concentration, fusion is essentially second order over a wide range of relatively low vesicle concentrations, whereas at higher vesicle concentrations the order is decreased. This suggests that at high vesicle concentrations (and at relatively low Ca2+ concentrations) aggregation may proceed faster than fusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bi00567a011

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 490

Metadata

Authors
Wilschut, J., Duzgunes, N., Fraley, R., & Papahadjopoulos, D.
Venue
Biochemistry
Published
1980-12-01
Volume
19
Issue
26
Pages
6011-6021
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W2015859497
Cited by
490
References
1
FWCI
8.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Studies on the mechanism of membrane fusion: kinetics of calcium ion induced fusion of phosphatidylserine vesicles followed by a new assay for mixing of aqueous vesicle contents. https://app.cochat.ai/papers/10.1021/bi00567a011
The paper
Wilschut, J., Duzgunes, N., Fraley, R., & Papahadjopoulos, D. (1980). Studies on the mechanism of membrane fusion: kinetics of calcium ion induced fusion of phosphatidylserine vesicles followed by a new assay for mixing of aqueous vesicle contents. Biochemistry. https://doi.org/10.1021/bi00567a011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.