CoChat

Mass Spectrometric Assays for the Tandem Lesion 8,5‘-Cyclo-2‘-deoxyguanosine in Mammalian DNA

Jaruga, Pawel, Birincioglu, Mustafa, Rodriguez, Henry, Dizdaroglu, Miral · 2002 · Biochemistry
Cited by 86

The DOI matches its Crossref record.

Abstract

8,5'-Cyclopurine 2'-deoxynucleosides are among the major lesions in DNA that are formed by attack of hydroxyl radical. These compounds represent a concomitant damage to both sugar and base moieties of the same nucleoside and thus can be considered tandem lesions. Because of the presence of a covalent bond between the sugar and purine moieties, these tandem lesions are not repaired by base excision repair but by nucleotide excision repair. Thus, they may play a role in diseases with defective nucleotide excision repair. We recently reported the identification and quantification of 8,5'-cyclo-2'-deoxyadenosine (8,5'-cdAdo) in DNA by liquid chromatography/mass spectrometry with the isotope dilution technique (LC/IDMS) [Dizdaroglu, M., Jaruga, P., and Rodriguez, H. (2001) Free Radical Biol. Med. 30, 774-784]. In the present work, we investigated the measurement of 8,5'-cyclo-2'-deoxyguanosine (8,5'-cdGuo) in DNA by LC/IDMS. A methodology was developed for the separation of both (5'R)- and (5'S)-diastereomers of this compound in enzymic hydrolysates of DNA. The mass spectra were recorded using an atmospheric pressure ionization-electrospray process in the positive ionization mode. For quantification, stable isotope-labeled analogues of (5'R)-8,5'-cdGuo and (5'S)-8,5'-cdGuo were prepared and isolated by semipreparative LC to be used as internal standards. The sensitivity level of LC/MS in the selected ion monitoring mode (LC/MS-SIM) was determined to be approximately 15 fmol of these compounds on the LC column. The yield of 8,5'-cdGuo was measured in DNA exposed in aqueous solution to ionizing radiation at doses from 2.5 to 40 Gy. For comparison, gas chromatography/mass spectrometry with the isotope dilution technique (GC/IDMS) was also employed to measure both (5'R)-8,5'-cdGuo and (5'S)-8,5'-cdGuo in DNA. Both techniques yielded nearly identical results. The radiation chemical yield of 8,5'-cdGuo was similar to those of other major purine-derived lesions in DNA. The sensitivity level of GC/MS-SIM was determined to be significantly greater than that of LC/MS-SIM (1 vs 15 fmol). The background levels of (5'R)-8,5'-cdGuo and (5'S)-8,5'-cdGuo were measured in calf thymus DNA and in DNA samples isolated from three different types of cultured human cells. The levels of (5'R)-8,5'-cdGuo and (5'S)-8,5'-cdGuo were approximately 2 lesions/10(6) DNA nucleosides and 10 lesions/10(6) DNA nucleosides, respectively. No significant differences between tissues were observed in terms of these background levels. The results showed that both LC/IDMS and GC/IDMS are well suited for the sensitive detection and precise quantification of both (5'R)-8,5'-cdGuo and (5'S)-8,5'-cdGuo in DNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bi016004d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Jaruga, P., Birincioglu, M., Rodriguez, H., & Dizdaroglu, M.
Venue
Biochemistry
Published
2002-02-19
Volume
41
Issue
11
Pages
3703-3711
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W2027604638
Cited by
86
References
0
FWCI
2.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.