Site-Directed Fluorescence Studies of a Prokaryotic ClC Antiporter
The DOI matches its Crossref record.
Abstract
Channels and transporters of the ClC family serve a variety of physiological functions. Understanding of their gating and transport mechanisms remains incomplete, with disagreement over the extent of protein conformational change involved. Using site-directed fluorescence labeling, we probe ClC-ec1, a prokaryotic ClC, for transport-related structural rearrangements. We specifically label cysteines introduced at several positions in the R helix of ClC-ec1 with AlexaFluor 488, an environment-sensitive fluorophore, and demonstrate that the labeled mutants show H+/Cl- transport activity indistinguishable from that of the wild-type protein. At each position that we examined we observe fluorescence changes upon acidification over the same pH range that is known to activate transport. The fluorescence change is also sensitive to Cl- concentration; furthermore, the Cl- and H+ dependencies are coupled as would be expected if the fluorescence change reflected a conformational change required for transport. Together, the results suggest that the changes in fluorescence report protein conformational changes underlying the transport process. Labeled transporters mutated to remove a glutamate critical to proton-coupled chloride transport retain pH-dependent fluorescence changes, suggesting that multiple residues confer pH dependence on the transport mechanism. These results have implications for models of transport and gating in ClC channels and transporters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CLC Chloride Channels and Transporters: Structure, Function, Physiology, and Disease
Jentsch, T. J., & Pusch, M. (2018) · Physiological Reviews · doi:10.1152/physrev.00047.2017 · Cited by 448
Structure of a CLC chloride ion channel by cryo-electron microscopy
Park, E., Campbell, E. B., & MacKinnon, R. (2017) · Nature · doi:10.1038/nature20812 · Cited by 164
Synergism Between Halide Binding and Proton Transport in a CLC-type Exchanger
Accardi, A., Lobet, S., Williams, C., Miller, C., & Dutzler, R. (2006) · Journal of Molecular Biology · doi:10.1016/j.jmb.2006.07.081 · Cited by 106
Ion permeation through a Cl − -selective channel designed from a CLC Cl − /H + exchanger
Jayaram, H., Accardi, A., Wu, F., Williams, C., & Miller, C. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804503105 · Cited by 101
Structure and gating of CLC channels and exchangers
Accardi, A. (2015) · The Journal of Physiology · doi:10.1113/jp270575 · Cited by 78
Metadata
- Authors
- Bell, S. P., Curran, P. K., Choi, S., & Mindell, J. A.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-10
- Volume
- 45
- Issue
- 22
- Pages
- 6773-6782
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W1982444633
- Cited by
- 38
- References
- 0
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Site-Directed Fluorescence Studies of a Prokaryotic ClC Antiporter. https://app.cochat.ai/papers/10.1021/bi0523815
- The paper
- Bell, S. P., Curran, P. K., Choi, S., & Mindell, J. A. (2006). Site-Directed Fluorescence Studies of a Prokaryotic ClC Antiporter. Biochemistry. https://doi.org/10.1021/bi0523815
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.