Design of Heterotetrameric Coiled Coils: Evidence for Increased Stabilization by Glu-−Lys+Ion Pair Interactions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electrostatic interactions between charged amino acids often affect heterospecificity in coiled coils as evidenced by the interaction between the oncoproteins, fos and jun. Such interactions have been successfully exploited in the design of heteromeric coiled coils in a number of laboratories. It has been suggested that heterospecificity in these dimeric coiled-coil systems is driven not by specific electrostatic interactions in the heterodimers but rather by electrostatic repulsion acting to destabilize the homodimer state relative to the heterodimer state. We show that it is possible to design ion pair interactions that directly stabilize the heterotetrameric coiled-coil state. Synthetic peptides were used whose sequences are based on the C-terminal tetramerization domain of Lac repressor, as a model system for four-chain coiled coils (Fairman et al., 1995). These Lac-based peptides, containing either glutamic acid (Lac21E) or lysine (Lac21K) at all b and c heptad positions, only weakly self-associate but, when mixed, afford a highly stable heterotetramer. This study represents the first experimental evidence for the importance of the b and c heptad positions to the stability of coiled coils. Finally, pH dependence and NaCl dependence studies show that heterotetramer stability is driven by ion pair interactions between glutamate and lysine; these interactions contribute about 0.6 kcal/mol of stabilizing free energy for each potential glutamate-lysine pair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krylov, D., Mikhailenko, I., & Vinson, C. (1994) · The EMBO Journal · doi:10.1002/j.1460-2075.1994.tb06579.x · Cited by 269
Cited by
Coiled coils: new structures and new functions
LUPAS, A. (1996) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(96)10052-9 · Cited by 1,183
The Design of Coiled-Coil Structures and Assemblies
Woolfson, D. N. (2005) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(05)70004-8 · Cited by 585
Multicomponent peptide assemblies
Raymond, D. M., & Nilsson, B. L. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00115d · Cited by 346
Designing Heterodimeric Two-stranded α-Helical Coiled-coils
Litowski, J. R., & Hodges, R. S. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m204257200 · Cited by 298
Parry, D. A. D., Fraser, R. D. B., & Squire, J. M. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.01.016 · Cited by 264
Metadata
- Authors
- Fairman, R., Chao, H.-G., Lavoie, T. B., Villafranca, J. J., Matsueda, G. R., & Novotny, J.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 35
- Issue
- 9
- Pages
- 2824-2829
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2045015765
- Cited by
- 88
- References
- 1
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of Heterotetrameric Coiled Coils: Evidence for Increased Stabilization by Glu-−Lys+Ion Pair Interactions. https://app.cochat.ai/papers/10.1021/bi952784c
- The paper
- Fairman, R., Chao, H.-G., Lavoie, T. B., Villafranca, J. J., Matsueda, G. R., & Novotny, J. (1996). Design of Heterotetrameric Coiled Coils: Evidence for Increased Stabilization by Glu-−Lys+Ion Pair Interactions. Biochemistry. https://doi.org/10.1021/bi952784c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.