Cited by 35biodegradable polymer synthesis and propertiesPhotopolymerization techniques and applicationsBone Tissue Engineering Materials

Photopolymerization of Novel Degradable Networks for Orthopedic Applications

Anseth, Kristi S., Svaldi, Dina C., Laurencin, Cato T., Langer, Robert·1997·ACS Symposium Series

Abstract

Multifunctional anhydride monomers (and oligomers) were developed that react to form highly crosslinked polyanhydride networks. Functionalized monomers (and oligomers) of sebacic acid and 1,6-bis( p -carboxyphenoxy)hexane were synthesized and subsequently photopolymerized. The high concentration of double bonds in the system and the multifunctional nature of the monomer (two double bonds per monomer molecule) led to the formation of a highly crosslinked polymer system in a period of seconds, depending on the initiation rate. Because the crosslinks were hydrolyzable anhydride linkages, the material remained biodegradable and the rate of degradation could be controlled by changes in the network composition and the crosslinking density. The high degree of crosslinking facilitated enhancement of mechanical properties (as compared to their linear counterparts) and also promoted a surface controlled degradation mechanism. The ability to photoinitiate the polymerization could lead to a new generation of orthopaedic implants that would provide surgeons with tremendous ease of placement and greater flexibility in design of fracture fixation systems.

Integrity signals

Registry

Crossref · 10.1021/bk-1997-0673.ch014

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Compressive strengths of 30-40 MPa and tensile strengths of 15-27 MPa, similar to those of cancellous bone, have been reported for polyanhydrides.

    “Compressive strengths of 30-40 MPa, and tensile strengths of 15-27 MPa, similar to those of cancelleous bone, have been reported”

    From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as Anseth et al., 1997

Cited by

Sorted by citations

Authors
Anseth, K. S., Svaldi, D. C., Laurencin, C. T., & Langer, R.
Affiliations
  • University of Colorado Boulder (US)
  • Department of Chemical Engineering, University of Colorado, Campus Box 424, Boulder, CO 80309-0424
  • Department of Orthopaedic Surgery, Medical College of Pennsylvania and Hahnemann University, Philadelphia, PA 19129
  • Department of Chemical Engineering, E25-342, Massachusetts Institute of Technology, Cambridge, MA 02139
Venue
ACS Symposium Series
Published
1997-11-01
Pages
189-202
ISSN
  • 0097-6156 (ISSN-L)
  • 1947-5918
OpenAlex
W2501058771
Cited by
35
References
0
Citations by year
2026: 1 · 2024: 1 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1
FWCI
8.02
Type
conference paper
Language
en
Open access
closed
Locations
ACS symposium series (publishedVersion)
Funders
National Institutes of Health
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Chemistry › Organic Chemistry › Photopolymerization techniques and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
photopolymerization, polyanhydrides, biodegradable polymers, sebacic acid, crosslinked polymer networks, controlled degradation, crosslink density, mechanical properties, orthopedic implants, fracture fixation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review