The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Swelling and Mechanical Behaviors of Chemically Cross-Linked Hydrogels of Elastin-like Polypeptides
Abstract
Genetically engineered elastin-like polypeptides consisting of Val-Pro-Gly-X-Gly repeats, where X was chosen to be Lys every 7 or 17 pentapeptides (otherwise X was Val), were synthesized and expressed in E. coli, purified, and chemically cross-linked using tris-succinimidyl aminotriacetate to produce hydrogels. Swelling experiments indicate hydrogel mass decreases by 80-90% gradually over an approximate 50 degrees C temperature range. Gels ranged in stiffness from 0.24 to 3.7 kPa at 7 degrees C and from 1.6 to 15 kPa at 37 degrees C depending on protein concentration, lysine content, and molecular weight. Changes in gel stiffness and loss angle with cross-linking formulation suggest a low-temperature gel structure that is nearly completely elastic, where force is transmitted almost exclusively through fully extended polypeptide chains and chemical cross-links, and a high-temperature gel structure, where ELP chains are contracted and force is transmitted through chemical cross-links as well as frictional contact between polypeptide chains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current Protocols in Molecular Biology
(2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471142727 · Cited by 2,398
Purification of recombinant proteins by fusion with thermally-responsive polypeptides
Meyer, D. E., & Chilkoti, A. (1999) · Nature Biotechnology · doi:10.1038/15100 · Cited by 914
Self-citationWelsh, E. R., & Tirrell, D. A. (2000) · Biomacromolecules · doi:10.1021/bm0002914 · Cited by 215
McMillan, R. A., & Conticello, V. P. (2000) · Macromolecules · doi:10.1021/ma9921091 · Cited by 141
Microsystem Technology and Microrobotics
Fatikow, S., & Rembold, U. (1997) · Springer eBooks · doi:10.1007/978-3-662-03450-7 · Cited by 135
Pseudomuscular Gel Actuators for Advanced Robotics
Rossi, D. D., Suzuki, M., Osada, Y., & Morasso, P. (1992) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9200300105 · Cited by 57
Cited by
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Rheological properties of peptide-based hydrogels for biomedical and other applications
Yan, C., & Pochan, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b919449p · Cited by 800
Hydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
Advantages of RGD peptides for directing cell association with biomaterials
Bellis, S. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.029 · Cited by 745
Chemically Modified Biopolymers for the Formation of Biomedical Hydrogels
Muir, V. G., & Burdick, J. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00923 · Cited by 604
Peptide-based stimuli-responsive biomaterials
Mart, R. J., Osborne, R. D., Stevens, M. M., & Ulijn, R. V. (2006) · Soft Matter · doi:10.1039/b607706d · Cited by 583
Light-Controlled Graphene-Elastin Composite Hydrogel Actuators
Wang, E., Desai, M. S., & Lee, S.-W. (2013) · Nano Letters · doi:10.1021/nl401088b · Cited by 574
Medical device‐induced thrombosis: what causes it and how can we prevent it?
Jaffer, I. H., Fredenburgh, J. C., Hirsh, J., & Weitz, J. I. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12961 · Cited by 557
Multifunctional GelMA platforms with nanomaterials for advanced tissue therapeutics
Kurian, A. G., Singh, R. K., Patel, K. D., Lee, J.-H., & Kim, H.-W. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.06.027 · Cited by 444
Elastin‐like polypeptides: Biomedical applications of tunable biopolymers
MacEwan, S. R., & Chilkoti, A. (2010) · Peptide Science · doi:10.1002/bip.21327 · Cited by 424
Self-citationApplications of elastin-like polypeptides in tissue engineering
Nettles, D. L., Chilkoti, A., & Setton, L. A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.002 · Cited by 350
Self-citationPeptide-based biopolymers in biomedicine and biotechnology
Chow, D., Nunalee, M. L., Lim, D. W., Simnick, A. J., & Chilkoti, A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2008.04.004 · Cited by 327
Self-citationStimulus responsive peptide based materials
Löwik, D. W. P. M., Leunissen, E. H. P., van den Heuvel, M., Hansen, M. B., & van Hest, J. C. M. (2010) · Chemical Society Reviews · doi:10.1039/b914342b · Cited by 319
Chondrocytic differentiation of human adipose-derived adult stem cells in elastin-like polypeptide
Betre, H., Ong, S. R., Guilak, F., Chilkoti, A., Fermor, B., & Setton, L. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.071 · Cited by 314
Self-citationElastin‐like polypeptides as models of intrinsically disordered proteins
Roberts, S., Dzuricky, M., & Chilkoti, A. (2015) · FEBS Letters · doi:10.1016/j.febslet.2015.08.029 · Cited by 310
Self-citationMcHale, M. K., Setton, L. A., & Chilkoti, A. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1768 · Cited by 295
Self-citationGao, Y., Peng, K., & Mitragotri, S. (2021) · Advanced Materials · doi:10.1002/adma.202006362 · Cited by 295
Smart and genetically engineered biomaterials and drug delivery systems
Kopeček, J. (2003) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(03)00164-7 · Cited by 292
Zhang, Y., Avery, R. K., Vallmajo‐Martin, Q., Assmann, A., Vegh, A., Memic, A., Olsen, B. D., Annabi, N., & Khademhosseini, A. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201501489 · Cited by 270
Applications of elastin-like polypeptides in drug delivery
MacEwan, S. R., & Chilkoti, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.06.028 · Cited by 261
Self-citationNovel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Chung, C., Lampe, K. J., & Heilshorn, S. C. (2012) · Biomacromolecules · doi:10.1021/bm3015279 · Cited by 132
Injectable silk fibroin/polyurethane composite hydrogel for nucleus pulposus replacement
Hu, J., Chen, B., Guo, F., Du, J., Gu, P., Lin, X., Yang, W., Zhang, H., Lu, M., Huang, Y., et al. (2012) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-011-4533-y · Cited by 69
Metadata
- Authors
- Trabbic-Carlson, K., Setton, L. A., & Chilkoti, A.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-03-15
- Volume
- 4
- Issue
- 3
- Pages
- 572-580
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1964535384
- Cited by
- 277
- References
- 6
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.