Cited by 153Polymer Surface Interaction StudiesBlood Coagulation and Thrombosis MechanismsSurface Modification and Superhydrophobicity

Novel thromboresistant materials

Open access
Jordan, Sumanas W., Chaikof, Elliot L.·2007·Journal of Vascular Surgery

Abstract

The development of a clinically durable small-diameter vascular graft as well as permanently implantable biosensors and artificial organ systems that interface with blood, including the artificial heart, kidney, liver, and lung, remain limited by surface-induced thrombotic responses. Recent breakthroughs in materials science, along with a growing understanding of the molecular events that underlay thrombosis, has led to the design and clinical evaluation of a variety of biologically active coatings that inhibit components of the coagulation pathway and platelet responses by surface immobilization or controlled release of bioactive agents. This report reviews recent progress in generating synthetic thromboresistant surfaces that inhibit (1) protein and cell adsorption, (2) thrombin and fibrin formation, and (3) platelet activation and aggregation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jvs.2007.02.048

Cites

193 of 193 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other anticoagulants such as thrombomodulin, direct thrombin inhibitors, and antiplatelet drugs have been immobilized onto polymer surfaces to increase hemocompatibility with varying success.

    “Other anticoagulants such as thrombomodulin,36 direct thrombin inhibitors (e.g., hirudin42 and argatroban43), or antiplatelet drugs (e.g.: prostacyclin (PGI2))36,41,42 have also been immobilized onto polymer surfaces to increase their hemocompatibility, with varying degrees of success.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Part of this paper’s reference list could not be split into single entries.

Flagged first, then by citations

Research works printed but not linked: 7

  1. Albers M, Battistella VM, Romiti M, Rodrigues AAE, Pereira CAB. Meta-analysis of polytetrafluoroethylene bypass grafts to infrapopliteal arteries. J Vasc Surg 2003;37:1263-9.
  2. Serruys PW, Dejaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyn- drickx G, et al. A comparison of balloon-expandable-stent implanta- tion with balloon angioplasty in patients with coronary-artery disease. N Engl J Med 1994;331:489-95.
  3. Lyman DJ, Klein KG, Brash JJ, Fritzinger BK, Andrade JD, Banoma FS. Platelet interaction with protein coated surfaces. Thromb Diath Haemor Proc 1970;42:6.
  4. Kamath KR, Demeo D, Park K. Albumin grafting on polymer surfaces by gamma-irradiation. Abstr Pap Am Chem Soc 1993;206:202- POLY.
  5. Yoneyama T, Ishihara K, Nakabayashi N, Ito M, Mishima Y. Short- term in vivo evaluation of small-diameter vascular prosthesis composed of segmented poly(etherurethane) 2-methacryloyloxyethyl phospho- rylcholine polymer blend. J Biomed Mater Res 1998;43:15-20.
  6. Ishihara K, Iwasaki Y. Biocompatible elastomers composed of seg- mented polyurethane and 2-methacryloyloxyethyl phosphorylcholine polymer. Polym Adv Technol 2000;11:626-34.
  7. Hubbell JA. Pharmacological modification of materials. Cardiovasc Pathol 1993;2:S121-7.

Cited by

Sorted by citations

Authors
Jordan, S. W., & Chaikof, E. L.
Affiliations
  • Emory University (US)
  • Georgia Institute of Technology (US)
Corresponding author
Chaikof, Elliot L.
Venue
Journal of Vascular Surgery
Publisher
Elsevier BV
Published
2007-06
Volume
45
Issue
6
Pages
A104-A115
ISSN
0741-5214 (ISSN-L)
OpenAlex
W2111549066
Cited by
153
References
193
Citations by year
2026: 4 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 2 · 2020: 6 · 2019: 5 · 2018: 6 · 2017: 7 · 2016: 13 · 2015: 9 · 2014: 10 · 2013: 17 · 2012: 10
FWCI
0.36
Type
journal article
Language
en
Open access
Locations
  • Journal of Vascular Surgery (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of General Medical Sciences (T32GM008169)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
Keywords
thrombosis, vascular grafts, small-diameter vascular grafts, implantable biosensors, artificial organs, anticoagulant coatings, platelet activation, platelet aggregation, fibrin formation, thrombin, protein adsorption, cell adsorption
MeSH terms
Albumins, Animals, Anticoagulants, Biocompatible Materials, Blood Coagulation, Blood Vessel Prosthesis, Carbon, Elastin, Fibrin, Heparin, Humans, Phosphorylcholine, Platelet Aggregation Inhibitors, Polyethylene Glycols, Prosthesis Design, Thrombin, Thrombosis, Platelet Activation, Stents, Thrombomodulin, Blood Vessel Prosthesis Implantation, Nitric Oxide Donors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review