Heparin-Coupled Poly(poly(ethylene glycol) monomethacrylate)-Si(111) Hybrids and Their Blood Compatible Surfaces
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Well-defined (nearly monodispersed) poly(poly(ethylene glycol)monomethacrylate)-Si hybrids were prepared via surface-initiated atom transfer radical polymerization (ATRP) of the poly(ethylene glycol)monomethacrylate (PEGMA) macromonomer on the hydrogen-terminated Si(111) surface (Si-H surface). Both the active chloride groups at the chain ends (from the ATRP process) and the chloride groups converted from some ( approximately 32%) of the -OH groups of the Si-C bonded PEGMA polymer, or P(PEGMA), brushes were used as leaving groups for the covalent coupling of heparin. For the heparinized P(PEGMA)-Si hybrid surfaces, protein adsorption and platelet adhesion were significantly suppressed. The well-defined and dense P(PEGMA) brushes, prepared from surface-initiated ATRP, had allowed the immobilization of a relatively high concentration of heparin (about 14 mug/cm(2)). The resulting silicon surface exhibited significantly improved antithrombogenecity with a plasma recalcification time (PRT) of about 150 min. The persistence of high bioactivity for the immobilized heparin on the hybrid surfaces can be attributed to the biocompatibility of the PEGMA units, as well as their role as spacers in providing the immobilized heparin with a higher degree of conformational freedom in a more hydrophilic environment. Thus, the heparin-coupled P(PEGMA)-Si hybrids with anti-fouling and antithrombogenic surfaces are potentially useful in silicon-based implantable devices and tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymer brushes: surface-immobilized macromolecules
Zhao, B., & Brittain, W. J. (2000) · Progress in Polymer Science · doi:10.1016/s0079-6700(00)00012-5 · Cited by 1,628
Kidane, A. G., Salacinski, H., Tiwari, A., Bruckdorfer, K. R., & Seifalian, A. M. (2004) · Biomacromolecules · doi:10.1021/bm0344553 · Cited by 166
Cited by
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Zoppe, J. O., Ataman, N. C., Mocny, P., Wang, J., Moraes, J., & Klok, H.-A. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00314 · Cited by 1,046
Krishnamoorthy, M., Hakobyan, S., Ramstedt, M., & Gautrot, J. E. (2014) · Chemical Reviews · doi:10.1021/cr500252u · Cited by 604
Boyer, C., Corrigan, N. A., Jung, K., Nguyen, D., Nguyen, T.-K., Adnan, N. N. M., Oliver, S., Shanmugam, S., & Yeow, J. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00396 · Cited by 483
Metadata
- Authors
- Xu, F. J., Li, Y. L., Kang, E. T., & Neoh, K. G.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-04-08
- Volume
- 6
- Issue
- 3
- Pages
- 1759-1768
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2069202404
- Cited by
- 130
- References
- 2
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heparin-Coupled Poly(poly(ethylene glycol) monomethacrylate)-Si(111) Hybrids and Their Blood Compatible Surfaces. https://app.cochat.ai/papers/10.1021/bm050071w
- The paper
- Xu, F. J., Li, Y. L., Kang, E. T., & Neoh, K. G. (2005). Heparin-Coupled Poly(poly(ethylene glycol) monomethacrylate)-Si(111) Hybrids and Their Blood Compatible Surfaces. Biomacromolecules. https://doi.org/10.1021/bm050071w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.