The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Biodegradable Thermoresponsive Hydrogels for Aqueous Encapsulation and Controlled Release of Hydrophilic Model Drugs
Abstract
A series of hydrogels with both thermoresponsive and completely biodegradable properties was developed for aqueous encapsulation and controlled release of hydrophilic drugs in response to temperature change. The hydrogels were prepared in phosphate-buffered saline (pH 7.4) through free radical polymerization of N-isopropylacrylamide (NIPAAm) monomer and a dextran macromer containing multiple hydrolytically degradable oligolactate-2-hydroxyethyl methacrylate units (Dex-lactateHEMA). Swelling measurement results demonstrated that four gels with feeding weight ratios of NIPAAm:Dex-lactateHEMA = 7:2, 6:3, 5:4, and 4:5 (w/w) were thermoresponsive by showing a lower critical solution temperature at approximately 32 degrees C. The swelling and degradation of the hydrogels strongly depended on temperature and hydrogel composition. An empirical mathematical model was established to describe the fast water absorption at the early stage and deswelling at the late stage of the hydrogels at 37 degrees C. Two hydrophilic model drugs, methylene blue and bovine serum albumin, were loaded into the hydrogels during the synthesis process. The molecular size of the drugs, the hydrophilicity and degradation of the hydrogels, and temperature played important roles in controlling the drug release.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Copinet, A., Bertrand, C., Govindin, S., Coma, V., & Couturier, Y. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2003.11.038 · Cited by 288
Cited by
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Gaudana, R., Ananthula, H. K., Parenky, A., & Mitra, A. K. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9183-3 · Cited by 1,406
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Polysaccharide hydrogels for modified release formulations
Coviello, T., Matricardi, P., Marianecci, C., & Alhaique, F. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.01.004 · Cited by 996
In situ gelling hydrogels for pharmaceutical and biomedical applications
Van Tomme, S. R., Storm, G., & Hennink, W. E. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.01.057 · Cited by 626
Metadata
- Authors
- Huang, X., & Lowe, T. L.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-21
- Volume
- 6
- Issue
- 4
- Pages
- 2131-2139
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2008545278
- Cited by
- 181
- References
- 1
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.