The DOI matches its Crossref record.
Novel Injectable pH and Temperature Sensitive Block Copolymer Hydrogel
Abstract
A novel pH and temperature sensitive block copolymer was prepared by adding pH sensitive moiety to temperature sensitive block copolymer. This block copolymer solution showed a reversible sol-gel transition by a small pH change in the range of pH 7.4-8.0 and also by the temperature change in the region of body temperature. The very precise molecular weight control of block copolymer and the prudential tuning of hydrophilic-hydrophobic balance were needed to control the phase diagram. This block copolymer solution forms a gel at 37 degrees C, pH 7.4 (human body). When the block copolymer solution is at room temperature and pH 8.0 as a sol state, both the temperature and pH change are needed for the gelation. This material can be employed as injectable carriers for hydrophobic drugs and proteins, etc. Gelation inside the needle can be prevented by an increase in the temperature during injection, because it does not change into the gel form with only increasing temperature. This material can be used for even a long guide catheter into the body. The block copolymer hydrogel which shows the sol-gel transition by the small pH change from pH 8.0 to pH 7.4 has merits in the delivery system for protein and cells which show cytotoxicity in acidic (below pH 6.5) or basic (above pH 8.5) conditions. This block copolymer system could be used as a template technology for injectable delivery systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart micro/nanoparticles in stimulus-responsive drug/gene delivery systems
Karimi, M., Ghasemi, A., Sahandi Zangabad, P., Rahighi, R., Moosavi Basri, S. M., Mirshekari, H., Amiri, M., Shafaei Pishabad, Z., Aslani, A., Bozorgomid, M., et al. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00798d · Cited by 1,519
Responsive polymers in controlled drug delivery
Bajpai, A. K., Shukla, S. K., Bhanu, S., & Kankane, S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.005 · Cited by 1,391
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Stimuli-responsive polymers: Biomedical applications and challenges for clinical translation
Hoffman, A. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.11.004 · Cited by 759
Injectable Biodegradable Hydrogels
Nguyen, M. K., & Lee, D. S. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900402 · Cited by 481
Self-citation
Metadata
- Authors
- Shim, W. S., Yoo, J. S., Bae, Y. H., & Lee, D. S.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-09-29
- Volume
- 6
- Issue
- 6
- Pages
- 2930-2934
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1985485626
- Cited by
- 229
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel Injectable pH and Temperature Sensitive Block Copolymer Hydrogel. https://app.cochat.ai/papers/10.1021/bm050521k
- The paper
- Shim, W. S., Yoo, J. S., Bae, Y. H., & Lee, D. S. (2005). Novel Injectable pH and Temperature Sensitive Block Copolymer Hydrogel. Biomacromolecules. https://doi.org/10.1021/bm050521k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.