Thermogelling Aqueous Solutions of Alternating Multiblock Copolymers of Poly(l-lactic acid) and Poly(ethylene glycol)
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We are reporting alternating multiblock copolymers of poly(L-lactic acid)/poly(ethylene glycol) aqueous solution (> 15 wt %) undergoing sol-gel-sol transition as the temperature increases from 20 to 60 degrees C. Micelles of the multiblock copolymers (in water) are about 20 nm in radius at low temperature. They are aggregated to a larger size as the temperature increases, which should play a critical role in the sol-to-gel transition. The transition temperature and gel window were affected by the molecular weight and composition of the multiblock copolymer. In particular, the aqueous solution of an alternating multiblock copolymer (Mn approximately 6700 daltons) prepared from poly(ethylene glycol) (Mn approximately 600 daltons) and poly(L-lactic acid) (Mn approximately 1300 daltons) showed a maximum modulus at body temperature (37 degrees C). The in situ gel forming ability of the polymer aqueous solution in vivo as well as in vitro indicates that it can be a promising injectable biomaterial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ-forming hydrogels--review of temperature-sensitive systems
Ruel-Gariépy, E., & Leroux, J.-C. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.019 · Cited by 1,297
Designing biodegradable multiblock PCL/PLA thermoplastic elastomers
Cohn, D., & Hotovely Salomon, A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.052 · Cited by 355
Cited by
Complexity in biomaterials for tissue engineering
Place, E. S., Evans, N. D., & Stevens, M. M. (2009) · Nature Materials · doi:10.1038/nmat2441 · Cited by 1,728
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Injectable hydrogels as unique biomedical materials
Yu, L., & Ding, J. (2008) · Chemical Society Reviews · doi:10.1039/b713009k · Cited by 1,545
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Metadata
- Authors
- Lee, J., Bae, Y. H., Sohn, Y. S., & Jeong, B.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-04-29
- Volume
- 7
- Issue
- 6
- Pages
- 1729-1734
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2005644896
- Cited by
- 101
- References
- 2
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermogelling Aqueous Solutions of Alternating Multiblock Copolymers of Poly(l-lactic acid) and Poly(ethylene glycol). https://app.cochat.ai/papers/10.1021/bm0600062
- The paper
- Lee, J., Bae, Y. H., Sohn, Y. S., & Jeong, B. (2006). Thermogelling Aqueous Solutions of Alternating Multiblock Copolymers of Poly(l-lactic acid) and Poly(ethylene glycol). Biomacromolecules. https://doi.org/10.1021/bm0600062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.