Sulfonamide-Based pH- and Temperature-Sensitive Biodegradable Block Copolymer Hydrogels
The DOI matches its Crossref record.
Abstract
Novel pH- and temperature-sensitive biodegradable poly(epsilon-caprolactone-co-lactide)-poly(ethylene glycol) (PCLA-PEG) block copolymers were synthesized with oligomeric sulfamethazine (OSM) end groups (OSM-PCLA-PEG-PCLA-OSM). Aqueous solutions of these block copolymers have shown sol-gel transition behavior upon both temperature and pH changes under physiological conditions (37 degrees C, pH 7.4). The sol-gel transition of these block copolymer solutions was fine-tuned by controlling the PEG length, the hydrophobic to hydrophilic block ratio (PCLA/PEG), and the molecular weight of the sulfamethazine oligomer. Since changes in temperature do not induce gel formation in this pH- and temperature-sensitive block copolymer solution, this hydrogel can be employed as an injectable carrier using a long guide catheter into the body. In addition, the pH of the block copolymer solution showed no change following PCLA degradation over 1 month, and no indication of gel collapse was observed on addition of buffer solution. As such, these properties make the OSM-PCLA-PEG-PCLA-OSM hydrogel an ideal candidate for use as an injectable carrier for certain protein-based drugs known to denature in low-pH environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Lee, K., Silva, E. A., & Mooney, D. J. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0223 · Cited by 1,386
Hydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
Ge, Z., & Liu, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60048c · Cited by 914
In situ gelling stimuli-sensitive block copolymer hydrogels for drug delivery
He, C., Kim, S. W., & Lee, D. S. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.005 · Cited by 867
Self-citation
Metadata
- Authors
- Shim, W. S., Kim, S. W., & Lee, D. S.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-05
- Volume
- 7
- Issue
- 6
- Pages
- 1935-1941
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2015441296
- Cited by
- 121
- References
- 0
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sulfonamide-Based pH- and Temperature-Sensitive Biodegradable Block Copolymer Hydrogels. https://app.cochat.ai/papers/10.1021/bm0600567
- The paper
- Shim, W. S., Kim, S. W., & Lee, D. S. (2006). Sulfonamide-Based pH- and Temperature-Sensitive Biodegradable Block Copolymer Hydrogels. Biomacromolecules. https://doi.org/10.1021/bm0600567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.