The DOI matches its Crossref record.
Synthesis and Volume Phase Transitions of Glucose-Sensitive Microgels
Abstract
By the functionalization of poly(N-isopropylacrylamide-co-acrylic acid) microgels with 3-aminophenylboronic acid (APBA) via carbodiimide coupling, nearly monodisperse glucose-sensitive P(NIPAM-PBA) microgels with a diameter of several hundred nanometers were synthesized in aqueous media. Dynamic laser light scattering was used to study the glucose-sensitive and thermosensitive behaviors of the resultant microgels under various conditions. The introduction of the hydrophobic phenylboronic acid (PBA) group significantly decreases the volume phase transition temperature of the resultant microgels. As a result, the P(NIPAM-PBA) microgels with a 10.0 mol % PBA content are in a collapsed state at room temperature. However, the addition of glucose makes the microgels swell dramatically. The glucose-sensitivity of the PBA-containing microgels relies on the stabilization of the charged phenylborate ions by binding with glucose, which can convert more hydrophobic PBA groups to the hydrophilic phenylborate ions. The presence of glucose also induces a two-stage volume phase transition of the P(NIPAM-PBA) microgels, which is explained by the core-shell-like heterogeneous structure of the microgels induced by the formation of the unique glucose-bis(boronate) complex in the "core" area of the microgels. The effects of pH, ionic strength, and PBA content on the glucose sensitivity of the P(NIPAM-PBA) microgels were investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Future perspectives and recent advances in stimuli-responsive materials
Roy, D., Cambre, J. N., & Sumerlin, B. S. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.008 · Cited by 1,474
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Synthesis and Applications of Boronic Acid-Containing Polymers: From Materials to Medicine
Brooks, W. L. A., & Sumerlin, B. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00300 · Cited by 981
Nanogels and Microgels: From Model Colloids to Applications, Recent Developments, and Future Trends
Karg, M., Pich, A., Hellweg, T., Hoare, T., Lyon, L. A., Crassous, J. J., Suzuki, D., Gumerov, R. A., Schneider, S., Potemkin, I. I., et al. (2019) · Langmuir · doi:10.1021/acs.langmuir.8b04304 · Cited by 658
PNIPAM microgels for biomedical applications: from dispersed particles to 3D assemblies
Guan, Y., & Zhang, Y. (2011) · Soft Matter · doi:10.1039/c0sm01541e · Cited by 459
Self-citationBoronic acid-containing hydrogels: synthesis and their applications
Guan, Y., & Zhang, Y. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60152h · Cited by 452
Self-citationBiomedical applications of boronic acid polymers
Cambre, J. N., & Sumerlin, B. S. (2011) · Polymer · doi:10.1016/j.polymer.2011.07.057 · Cited by 435
Carbon nanotubes as optical biomedical sensors
Kruss, S., Hilmer, A. J., Zhang, J., Reuel, N. F., Mu, B., & Strano, M. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.015 · Cited by 413
Stimulus responsive nanogels for drug delivery
Zha, L., Banik, B., & Alexis, F. (2011) · Soft Matter · doi:10.1039/c0sm01307b · Cited by 391
Organization of Glucose-Responsive Systems and Their Properties
Wu, Q., Wang, L., Yu, H., Wang, J., & Chen, Z. (2011) · Chemical Reviews · doi:10.1021/cr200027j · Cited by 374
Kim, K. T., Cornelissen, J. J. L. M., Nolte, R. J. M., & van Hest, J. C. M. (2009) · Advanced Materials · doi:10.1002/adma.200900300 · Cited by 355
Glucose‐Sensitive Hydrogel Optical Fibers Functionalized with Phenylboronic Acid
Yetisen, A. K., Jiang, N., Fallahi, A., Montelongo, Y., Ruiz‐Esparza, G. U., Tamayol, A., Zhang, Y. S., Mahmood, I., Yang, S., Kim, K. S., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606380 · Cited by 311
Self-citationWu, W., Mitra, N., Yan, E. C. Y., & Zhou, S. (2010) · ACS Nano · doi:10.1021/nn1008319 · Cited by 309
Self-citationGlucose‐Responsive Insulin and Delivery Systems: Innovation and Translation
Wang, J., Wang, Z., Yu, J., Kahkoska, A. R., Buse, J. B., & Gu, Z. (2020) · Advanced Materials · doi:10.1002/adma.201902004 · Cited by 295
Wang, H., Chen, Q., & Zhou, S. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00399d · Cited by 260
Self-citation
Metadata
- Authors
- Zhang, Y., Guan, Y., & Zhou, S.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-09-30
- Volume
- 7
- Issue
- 11
- Pages
- 3196-3201
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2026578840
- Cited by
- 249
- References
- 0
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.