Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

Injectable pH- and Temperature-Responsive Poly(N-isopropylacrylamide-co-propylacrylic acid) Copolymers for Delivery of Angiogenic Growth Factors

Open access
Garbern, Jessica C., Hoffman, Allan S., Stayton, Patrick S.·2010·Biomacromolecules

Abstract

A new sharply pH- and temperature-responsive hydrogel system was designed for delivering drugs to regions of local acidosis, as found in wound healing, tumor sites, or sites of ischemia. The reversible addition-fragmentation chain transfer (RAFT) polymerization technique was used to synthesize copolymers of N-isopropylacrylamide (NIPAAM) and propylacrylic acid (PAA) with feed ratios of PAA between 0 and 20 mol %. The pH-responsive viscoelastic properties of these materials as a function of pH and temperature were quantified by rheometry. At physiologic pH (7.4) and 5 wt %, the polymer did not form gels but rather remained soluble at temperatures as high as 50 degrees C. At lower pH values (pH ca. 5.5 and below), the polymer was liquid at 20 degrees C, but exhibited a sol-gel phase transformation with increasing temperature and existed as a physical gel at 37 degrees C. Incorporation of the hydrophobic monomer, butyl acrylate, into the random copolymer raised the pH of gel formation to greater than 6.0 at 37 degrees C. Drug loading studies demonstrated that p(NIPAAm-co-PAA) hydrogels are able to maintain the bioactivity of basic fibroblast growth factor following storage in hydrogel for 40 h and can provide sustained pH-dependent release of vascular endothelial growth factor over a period of at least three weeks. This hydrogel system will thus gel at controllable acidic pH values upon injection, and is designed to undergo gradual dissolution as it performs its drug delivery function and the ischemic site returns to physiological pH.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/bm100318z

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Garbern, J. C., Hoffman, A. S., & Stayton, P. S.
Venue
Biomacromolecules
Published
2010-05-28
Volume
11
Issue
7
Pages
1833-1839
ISSN
  • 1525-7797 (ISSN-L)
  • 1526-4602
OpenAlex
W2040076009
Cited by
182
References
0
FWCI
8.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Injectable pH- and Temperature-Responsive Poly(N-isopropylacrylamide-co-propylacrylic acid) Copolymers for Delivery of Angiogenic Growth Factors. https://app.cochat.ai/papers/10.1021/bm100318z
The paper
Garbern, J. C., Hoffman, A. S., & Stayton, P. S. (2010). Injectable pH- and Temperature-Responsive Poly(N-isopropylacrylamide-co-propylacrylic acid) Copolymers for Delivery of Angiogenic Growth Factors. Biomacromolecules. https://doi.org/10.1021/bm100318z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.