The DOI matches its Crossref record.
Macroporous Silk Fibroin Cryogels
Abstract
Silk fibroin cryogels with remarkable properties were obtained from frozen fibroin solutions (4.2-12.6%) at subzero temperatures between -5 and -22 °C. This was achieved by the addition of ethylene glycol diglycidyl ether (EGDE) into the cryogelation system. EGDE triggers the conformational transition of fibroin from random coil to β-sheet structure and hence fibroin gelation. One of the unique features of fibroin cryogels is their elasticity that allows them to resist complete compression without any crack development, during which water inside the cryogel is removed. The compressed cryogel immediately swells during unloading to recover its original shape. The scaffolds obtained by freeze-drying of the cryogels consist of regular, interconnected pores of diameters ranging from 50 to 10 μm that could be regulated by the synthesis parameters. The mechanical compressive strength and the modulus of the scaffolds increase with decreasing pore diameter, that is, with decreasing gelation temperature or, with increasing fibroin or EGDE concentrations in the feed. The scaffolds produced at 12.6% fibroin exhibit a very high compressive modulus (50 MPa) making them good candidates as bone scaffold materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Silk fibroin as biomaterial for bone tissue engineering
Melke, J., Midha, S., Ghosh, S., Ito, K., & Hofmann, S. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.09.005 · Cited by 789
Latest Advances in Cryogel Technology for Biomedical Applications
Memic, A., Colombani, T., Eggermont, L. J., Rezaeeyazdi, M., Steingold, J., Rogers, Z. J., Navare, K. J., Mohammed, H. S., & Bencherif, S. A. (2019) · Advanced Therapeutics · doi:10.1002/adtp.201800114 · Cited by 310
Reizabal, A., Costa, C. M., Pérez‐Álvarez, L., Vilas‐Vilela, J. L., & Lanceros‐Méndez, S. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202210764 · Cited by 285
A comprehensive review of cryogels and their roles in tissue engineering applications
Hixon, K. R., Lu, T., & Sell, S. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.033 · Cited by 280
Low‐Density Open Cellular Sponges as Functional Materials
Jiang, S., Agarwal, S., & Greiner, A. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201700684 · Cited by 217
Chemical, thermal, time, and enzymatic stability of silk materials with silk I structure
Zhao, M., Qi, Z., Tao, X., Newkirk, C., Hu, X., & Lu, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22084136 · Cited by 130
Kim, H. H., Kim, J. W., Choi, J., Park, Y. H., & Ki, C. S. (2018) · Polymer · doi:10.1016/j.polymer.2018.08.019 · Cited by 53
Stretchable silk fibroin hydrogels
Oral, C. B., Yetiskin, B., & Okay, O. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2020.08.040 · Cited by 35
Self-citation
Metadata
- Authors
- Ak, F., Oztoprak, Z., Karakutuk, I., & Okay, O.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-13
- Volume
- 14
- Issue
- 3
- Pages
- 719-727
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2312237494
- Cited by
- 160
- References
- 0
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.