The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Carrageenan-Based Hydrogels for the Controlled Delivery of PDGF-BB in Bone Tissue Engineering Applications
Open accessAbstract
One of the major drawbacks found in most bone tissue engineering approaches developed so far consists in the lack of strategies to promote vascularisation. Some studies have addressed different issues that may enhance vascularisation in tissue engineered constructs, most of them involving the use of growth factors (GFs) that are involved in the restitution of the vascularity in a damaged zone. The use of sustained delivery systems might also play an important role in the re-establishment of angiogenesis. In this study, kappa-carrageenan, a naturally occurring polymer, was used to develop hydrogel beads with the ability to incorporate GFs with the purpose of establishing an effective angiogenesis mechanism. Some processing parameters were studied and their influence on the final bead properties was evaluated. Platelet derived growth factor (PDGF-BB) was selected as the angiogenic factor to incorporate in the developed beads, and the results demonstrate the achievement of an efficient encapsulation and controlled release profile matching those usually required for the development of a fully functional vascular network. In general, the obtained results demonstrate the potential of these systems for bone tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Cited by
3D printing of hydrogels: Rational design strategies and emerging biomedical applications
Li, J., Wu, C., Chu, P. K., & Gelinsky, M. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100543 · Cited by 862
Ahmed, T., & Aljaeid, B. (2016) · Drug Design, Development and Therapy · doi:10.2147/dddt.s99651 · Cited by 705
Sulfated Seaweed Polysaccharides as Multifunctional Materials in Drug Delivery Applications
Cunha, L., & Grenha, A. (2016) · Marine Drugs · doi:10.3390/md14030042 · Cited by 611
Scaffold: A Novel Carrier for Cell and Drug Delivery
Garg, T., Singh, O., Arora, S., & Murthy, R. S. R. (2012) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v29.i1.10 · Cited by 549
Application of xanthan gum as polysaccharide in tissue engineering: A review
Kumar, A., Rao, K. M., & Han, S. S. (2018) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2017.10.009 · Cited by 540
Metadata
- Authors
- Santo, V. E., Frias, A. M., Carida, M., Cancedda, R., Gomes, M. E., Mano, J. F., & Reis, R. L.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-04-22
- Volume
- 10
- Issue
- 6
- Pages
- 1392-1401
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2115908870
- Cited by
- 191
- References
- 1
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.