The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fabrication and Properties of the Electrospun Polylactide/Silk Fibroin-Gelatin Composite Tubular Scaffold
Abstract
In this study, a tubular scaffold composed of polylactide fibers (outside layer) and silk fibroin-gelatin fibers (inner layer) was fabricated successfully by electrospinning. Morphological, biomechanical, and dissolvable properties of the composite scaffolds were examined, in particular, biocompatibility of the scaffolds were evaluated in vitro and in vivo by means of cell culture and subcutaneous implantation test. The PLA/SF-gelatin tubular scaffolds, with porosity of approximately 82 +/- 2%, possessed appropriate breaking strength (2.21 +/- 0.18 MPa), pliability (60.58 +/- 1.23%), and suture retention strength (4.58 +/- 0.62 N). The burst pressure strength of the composite scaffolds reached 1596 +/- 20 mmHg, which is much greater than that of the native vessels. The composite scaffolds could hardly dissolve in the water; the water-dissolved rate was only 0.3 +/- 0.1%. MTT assay and SEM observation indicated that both 3T3 mouse fibroblasts and human umbilical vein endothelial cells could adhere, spread, and proliferate well on the composite tubular scaffolds after culturing for 14 and 21 days, respectively. The subcutaneous implantation results showed that macrophages and lymphocytes were not observed, which indicated that the composite scaffolds could induce minor inflammatory reactions in vivo. The PLA/SF-gelatin tubular scaffolds are biocompatible, possess appropriate biomechanical properties, and provide a favorable environment that supports the growth of cells, which shows that the composite tube can be considered as an ideal candidate for tissue engineering blood vessel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459
Cited by
Biopolymer-Based Hydrogels As Scaffolds for Tissue Engineering Applications: A Review
Van Vlierberghe, S., Dubruel, P., & Schacht, E. (2011) · Biomacromolecules · doi:10.1021/bm200083n · Cited by 1,716
Sell, S. A., Wolfe, P. S., Garg, K., McCool, J. M., Rodriguez, I. A., & Bowlin, G. L. (2010) · Polymers · doi:10.3390/polym2040522 · Cited by 578
Poly(lactic acid) nanofibrous scaffolds for tissue engineering
Santoro, M., Shah, S. R., Walker, J. L., & Mikos, A. G. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.019 · Cited by 485
Silk Fibroin in Tissue Engineering
Kasoju, N., & Bora, U. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200097 · Cited by 383
Composite materials based on silk proteins
Hardy, J. G., & Scheibel, T. R. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.005 · Cited by 322
Zheng, W., Wang, Z., Song, L., Zhao, Q., Zhang, J., Li, D., Wang, S., Han, J., Zheng, X.-L., Yang, Z., et al. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.12.047 · Cited by 288
Self-citation
Metadata
- Authors
- Wang, S., Zhang, Y., Wang, H., Yin, G., & Dong, Z.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-14
- Volume
- 10
- Issue
- 8
- Pages
- 2240-2244
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2019140350
- Cited by
- 160
- References
- 1
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.