The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Tuning the pH Responsiveness of β-Hairpin Peptide Folding, Self-Assembly, and Hydrogel Material Formation
Abstract
A design strategy to control the thermally triggered folding, self-assembly, and subsequent hydrogelation of amphiphilic beta-hairpin peptides in a pH-dependent manner is presented. Point substitutions of the lysine residues of the self-assembling peptide MAX1 were made to alter the net charge of the peptide. In turn, the electrostatic nature of the peptide directly influences the solution pH at which thermally triggered hydrogelation is permitted. CD spectroscopy and oscillatory rheology show that peptides of lower net positive charge are capable of folding and assembling into hydrogel material at lower values of pH at a given temperature. The pH sensitive folding and assembling behavior is not only dependent on the net peptide charge, but also on the exact position of substitution within the peptide sequence. TEM shows that these peptides self-assemble into hydrogels that are composed of well-defined fibrils with nonlaminated morphologies. TEM also indicates that fibril morphology is not influenced by making these sequence changes on the hydrophilic face of the hairpins. Rheology shows that the ultimate mechanical rigidity of these peptide hydrogels is dependent on the rate of folding and self-assembly. Peptides that fold and assemble faster afford more rigid gels. Ultimately, this design strategy yielded a peptide MAX1(K15E) that is capable of undergoing thermally triggered hydrogelation at physiological buffer conditions (pH 7.4, 150 NaCl, 37 degrees C).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Rationally designed mutations convert de novo amyloid-like fibrils into monomeric β-sheet proteins
Wang, W., & Hecht, M. H. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052706199 · Cited by 159
Cited by
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Shear-thinning hydrogels for biomedical applications
Guvendiren, M., Lu, H. D., & Burdick, J. A. (2012) · Soft Matter · doi:10.1039/c1sm06513k · Cited by 911
Designing degradable hydrogels for orthogonal control of cell microenvironments
Kharkar, P. M., Kiick, K. L., & Kloxin, A. M. (2013) · Chem. Soc. Rev. · doi:10.1039/c3cs60040h · Cited by 717
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Multi-component extracellular matrices based on peptide self-assembly
Collier, J. H., Rudra, J. S., Gasiorowski, J. Z., & Jung, J. P. (2010) · Chemical Society Reviews · doi:10.1039/b914337h · Cited by 229
Metadata
- Authors
- Rajagopal, K., Lamm, M. S., Haines-Butterick, L. A., Pochan, D. J., & Schneider, J. P.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-07
- Volume
- 10
- Issue
- 9
- Pages
- 2619-2625
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W1966161710
- Cited by
- 174
- References
- 4
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.