The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Situ Forming Hydrogels Based on Tyramine Conjugated 4-Arm-PPO-PEO via Enzymatic Oxidative Reaction
Abstract
Over the past decades, hydrogels have been widely studied as biomaterials for various biomedical applications like implants, drugs and cell delivery carriers because of their high biocompatibility, high water contents and excellent permeability for nutrients and metabolites. Especially, in situ forming hydrogel systems have received much attention because of their easy application based on minimal invasive techniques. Chemical cross-linking systems fabricated using enzymatic reactions have various advantages, such as high biocompatibility and easy control of reaction rates under mild condition. In this study, we report enzyme-triggered injectable and biodegradable hydrogels composed of Tetronic-tyramine conjugates. The Tetronic-tyramine conjugates were synthesized by first reacting Tetronic with succinic anhydride and subsequent conjugation with tyramine using DCC/NHS as coupling reagents. The chemical structure of Tetronic-succinic anhydride-tyramine (Tet-SA-TA) copolymer was characterized by (1)H NMR and FTIR. The hydrogels were prepared from a Tet-SA-TA solution above 3 wt % in the presence of horseradish peroxidase (HRP) and H(2)O(2) under physiological conditions. Their mechanical property, gelation time, swelling ratio and degradation time were evaluated at different polymer, HRP, and H(2)O(2) concentrations. In addition, a cyto-compatibility study was performed using the MC3T3-E1 cell line. In the cytotoxicity test, it was clear that the Tet-SA-TA hydrogel had no apparent cytotoxicity except for the hydrogel formed with 0.25 wt % H(2)O(2) due to the cytotoxicity of residual H(2)O(2). In conclusion, the obtained results demonstrated that the Tet-SA-TA hydrogel has great potential for use as an injectable scaffold for tissue engineering and as a drug carrier for controlled drug delivery systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Cited by
Enzyme-catalyzed crosslinkable hydrogels: Emerging strategies for tissue engineering
Moreira Teixeira, L. S., Feijen, J., van Blitterswijk, C. A., Dijkstra, P. J., & Karperien, M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.067 · Cited by 615
Polymeric hydrogel systems as emerging biomaterial platforms to enable hemostasis and wound healing
Pourshahrestani, S., Zeimaran, E., Kadri, N. A., Mutlu, N., & Boccaccini, A. R. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000905 · Cited by 448
Bio-inspired adhesive catechol-conjugated chitosan for biomedical applications: A mini review
Ryu, J. H., Hong, S., & Lee, H. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.08.043 · Cited by 428
Recent progress of in situ formed gels for biomedical applications
Ko, D. Y., Shinde, U. P., Yeon, B., & Jeong, B. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.08.002 · Cited by 416
Hydrogels for tissue engineering and regenerative medicine
Hunt, J. A., Chen, R., van Veen, T., & Bryan, N. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00775a · Cited by 377
Metadata
- Authors
- Park, K. M., Shin, Y. M., Joung, Y. K., Shin, H., & Park, K. D.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-02-01
- Volume
- 11
- Issue
- 3
- Pages
- 706-712
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2032527828
- Cited by
- 169
- References
- 1
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.