Simultaneous Measurement of 19 Components in Serum‐Containing Animal Cell Culture Media by Fourier Transform Near‐Infrared Spectroscopy
The DOI matches its Crossref record.
Abstract
Animal cell cultures generate maximal amounts of desired products when maintained in a controlled environment with low and constant concentrations of nutrients and wastes. Traditionally this has involved slow addition of glucose and glutamine; however, recent studies have indicated that a number of low concentration amino acids are required to prevent initiation of apoptosis. Therefore, optimal control of animal cell cultures will likely require measurement of a large number of chemical components. We present here the evaluation of a near‐infrared spectroscopic (NIRS) monitoring scheme to quantify 19 cellular nutrients and wastes in culture medium with and without serum. The components include glucose, lactate, ammonia, pyruvate, glutamine, and 14 other amino acids. Spectroscopic calibrations were generated for a synthetic version of a standard culture medium (DMEM) in which the concentrations of 17 DMEM components and ammonia and lactate were varied in a random fashion. This randomization provides a stringent evaluation of the measurement scheme. Reasonably accurate measurements of these 19 components could be accomplished in the absence or presence of 10% horse serum by volume with percent errors ranging from 3% to 37%. Analytes with concentrations as low as 0.3 mM could be reliably quantified. The presence of serum, when properly included in the calibration, has little effect on measurement error. These results provide an important step toward application of NIRS for monitoring the large number of varying components of animal cell cultivations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell culture processes for monoclonal antibody production
Li, F., Vijayasankaran, N., Shen, A. (., Kiss, R., & Amanullah, A. (2010) · mAbs · doi:10.4161/mabs.2.5.12720 · Cited by 739
On-Line Monitoring of Large Cultivations of Microalgae and Cyanobacteria
Havlik, I., Lindner, P., Scheper, T., & Reardon, K. F. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.04.005 · Cited by 131
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124
Metadata
- Authors
- Riley, M. R., Crider, H. M., Nite, M. E., Garcia, R. A., Woo, J., & Wegge, R. M.
- Venue
- Biotechnology Progress
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 17
- Issue
- 2
- Pages
- 376-378
- ISSN
- 1520-6033 (ISSN-L)
- 8756-7938
- OpenAlex
- W1528513917
- Cited by
- 46
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.