The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Molecular Docking of Intercalators and Groove-Binders to Nucleic Acids Using Autodock and Surflex
Open accessAbstract
The molecular docking tools Autodock and Surflex accurately reproduce the crystallographic structures of a collection of small molecule ligands that have been shown to bind nucleic acids. Docking studies were performed with the intercalators daunorubicin and ellipticine and the minor groove binders distamycin and pentamidine. Autodock and Surflex dock daunorubicin and distamycin to their nucleic acid targets within a resolution of approximately 2 A, which is similar to the limit of the crystal structure resolution. However, for the top ranked poses, Autodock and Surflex both dock ellipticine into the correct site but in a different orientation compared to the crystal structure. This appears not only to be partly related to the symmetry of the target nucleic acid, as ellipticine is able to dock from either side of the intercalation site, but also due to the shape of the ligand and docking accuracy. Surflex docks pentamidine in a symmetrically equivalent orientation relative to the crystal structure, while Autodock was able to dock this molecule in the original orientation. In the case of the Surflex docking of pentamidine, the initial rmsd is misleading, given the symmetrical structure of pentamidine. Importantly, the ranking functions of both of these programs are able to return a top pose within approximately 2 A rmsd for daunorubicin, distamycin, and pentamidine and approximately 3 A rmsd for ellipticine compared to their respective crystal structures. Some docking challenges and potential pitfalls are explored, such as the importance of hydrogen treatment on ligands as well as the scoring functions of Autodock and Surflex. Overall for this set of complexes, Surflex is preferred over Autodock for virtual screening, as although the results are comparable, Surflex has significantly faster performance and ease of use under the optimal software conditions tested. These experiments show that molecular docking techniques can be successfully extended to include nucleic acid targets, a finding which has important implications for virtual screening applications and in the design of new small molecules to target therapeutically relevant morphologies of nucleic acids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A semiempirical free energy force field with charge‐based desolvation
Huey, R., Morris, G. M., Olson, A. J., & Goodsell, D. S. (2007) · Journal of Computational Chemistry · doi:10.1002/jcc.20634 · Cited by 2,246
Principles of docking: An overview of search algorithms and a guide to scoring functions
Halperin, I., Ma, B., Wolfson, H., & Nussinov, R. (2002) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.10115 · Cited by 1,294
Comparative evaluation of eight docking tools for docking and virtual screening accuracy
Kellenberger, E., Rodrigo, J., Muller, P., & Rognan, D. (2004) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.20149 · Cited by 577
Moitessier, N., Englebienne, P., Lee, D., Lawandi, J., & Corbeil, C. R. (2008) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707515 · Cited by 514
Cited by
Can we trust docking results? Evaluation of seven commonly used programs on PDBbind database
Plewczynski, D., Łaźniewski, M., Augustyniak, R., & Ginalski, K. (2011) · Journal of Computational Chemistry · doi:10.1002/jcc.21643 · Cited by 407
Rescifina, A., Zagni, C., Varrica, M. G., Pistarà, V., & Corsaro, A. (2014) · European Journal of Medicinal Chemistry · doi:10.1016/j.ejmech.2013.11.029 · Cited by 274
Wu, B., Zhang, Y., Kong, J., Zhang, X., & Cheng, S. (2009) · Toxicology Letters · doi:10.1016/j.toxlet.2009.08.005 · Cited by 46
Yang, L., & Pan, J. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20153800 · Cited by 12
Metadata
- Authors
- Holt, P. A., Chaires, J. B., & Trent, J. O.
- Venue
- Journal of Chemical Information and Modeling
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-07-22
- Volume
- 48
- Issue
- 8
- Pages
- 1602-1615
- ISSN
- 1549-9596 (ISSN-L)
- 1549-960X
- OpenAlex
- W1967081738
- Cited by
- 225
- References
- 4
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.