Toward Highly Active Two-Photon Absorbing Liquids. Synthesis and Characterization of 1,3,5-Triazine-Based Octupolar Molecules

Kannan, Ramamurthi, He, Guang S., Lin, Tzu-Chau, Prasad, Paras N., Vaia, Richard A., Tan, Loon-Seng·2004·Chemistry of Materials

Abstract

Three novel two-photon absorbing (TPA) chromophores with 1,3,5-triazine as the π-electron deficient core, dialkylfluorene as aromatic bridges, and diphenylamino groups as the electron-donating end-groups were prepared. Designated as AF-450 (2,4,6-tris[7-(diphenylamino)-9,9-didecylfluoren-2-yl]-1,3,5-triazine), AF-455 (2,4,6-tris[9,9-bis(3,7-dimethyloctyl)-7-(diphenylamino)-fluoren-2yl]-1,3,5-triazine), and AF-457 (2,4,6-tris[(7-(diphenylamino)-9,9-diprop-2-enylfluoren-2-yl]-1,3,5-triazine), their overall molecular structure and local symmetry ( D 3 h ) are similar to those of previously reported three-armed AF-350 ( N, N, N -tris[4-{7-(2-benzothiazolyl)-9,9-diethylfluoren-2-yl}phenyl]amine) and AF-380 ( N, N, N,-tris[7-(2-benzothiazolyl)-9,9-diethylfluoren-2-yl]amine). Among the family of AFX chromophores previously reported by us, AF-450 possesses one of the largest effective TPA cross-sections (σ 2 ‘ = 39 500 × 10 - 50 cm 4 -sec/photon-molecule, or 39 500 GM) as determined by nonlinear transmission method in the nanosecond regime at 800 nm. In contrast, AF-455, a mixture of stereoisomers with the same chemical formula as AF-450, is a glassy material that becomes fluid (molasses-like) upon heating at 70−80 °C and has noticeably smaller effective σ 2 ‘ value (33 300 GM). AF-457 (σ 2 ‘ = 27 800 GM) with six allyl side groups was prepared as a precursor toward the synthesis of a TPA liquid. The intrinsic TPA cross-sections of these chromophores were also determined as a function of excitation wavelengths via a femtosecond white-light continuum generation and direct degenerate-TPA measurement technique. At the TPA peaks ∼779 nm, their σ 2 ‘ values are 216, 214, and 199 GM (±15%) for AF-450, AF-455, and AF-457, in that order. They are in the same trend as the nanosecond values, albeit two orders of magnitude lower.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/cm034358g

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 225

Metadata

Authors
Kannan, R., He, G. S., Lin, T.-C., Prasad, P. N., Vaia, R. A., & Tan, L.-S.
Venue
Chemistry of Materials
Published
2003-11-22
Volume
16
Issue
1
Pages
185-194
ISSN
  • 0897-4756 (ISSN-L)
  • 1520-5002
OpenAlex
W1975689256
Cited by
225
References
2
FWCI
9.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.