The DOI matches its Crossref record.
Effect of Mild Nitric Acid Oxidation on Dispersability, Size, and Structure of Single-Walled Carbon Nanotubes
Abstract
Oxidation of single-walled carbon nanotubes (SWNTs) with nitric acid increases their dispersability in water, methanol, and N, N -dimethylformamide. Two oxidation protocols, sonication in 8 M HNO 3 at 40 °C and reflux in 2.6 M HNO 3, have been examined using SWNTs produced by the CoMoCat, HiPco, and pulsed laser vaporization (PLV) methods. The dispersability of all types of nanotubes increased substantially after 1 h of sonication and after 2−4 h of reflux. Longer treatments resulted in little further improvement in dispersability and at reflux degraded the SWNTs. Stable dispersions of CoMoCat SWNTs in DMF at concentrations as high as 0.4 g/L were achieved without the use of surfactants or polymers. Raman spectroscopy showed greater covalent functionalization of the SWNTs by the reflux procedure than by the sonication procedure. Concurrent with improved dispersability, oxidation resulted in smaller diameters and shorter lengths as determined from AFM images, which show mostly bundles rather than individual tubes. The lengths of SWNTs after oxidation decreased in the order PLV > HiPco > CoMoCat. Recommendations for the method of conditioning of the various types of SWNTs depend on their intended use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on carbon nanotubes and graphene as fillers in reinforced polymer nanocomposites
Mittal, G., Dhand, V., Rhee, K. Y., Park, S.-J., & Lee, W. R. (2015) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2014.03.022 · Cited by 1,371
Kweon, D. H., Okyay, M. S., Kim, S.-J., Jeon, J.-P., Noh, H.-J., Park, N., Mahmood, J., & Baek, J.-B. (2020) · Nature Communications · doi:10.1038/s41467-020-15069-3 · Cited by 546
Maiti, U. N., Lee, W. J., Lee, J. M., Oh, Y., Kim, J. Y., Kim, J. E., Shim, J., Han, T. H., & Kim, S. O. (2014) · Advanced Materials · doi:10.1002/adma.201303265 · Cited by 544
Advances in Tailoring Resorcinol‐Formaldehyde Organic and Carbon Gels
ElKhatat, A. M., & Al‐Muhtaseb, S. A. (2011) · Advanced Materials · doi:10.1002/adma.201100283 · Cited by 488
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Pradhan, B., Roy, S., Srivastava, S. K., & Saxena, A. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41818 · Cited by 46
Metadata
- Authors
- Tchoul, M. N., Ford, W. T., Lolli, G., Resasco, D. E., & Arepalli, S.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-12
- Volume
- 19
- Issue
- 23
- Pages
- 5765-5772
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W1975686958
- Cited by
- 251
- References
- 0
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.