Fabrication of Arrays of Lead Zirconate Titanate (PZT) Nanodots via Block Copolymer Self-Assembly
Abstract
This Article presents a simple methodology for the fabrication of two-dimensional arrays of lead zirconate titanate (PZT) nanodots on n-doped Si substrates via the directed self-assembly of PS- b -PEO block copolymer templates. The approach produces highly ordered PZT nanodot patterns, with lateral widths and heights as small as 20 and 10 nm, respectively, and a coverage density as high as ∼68 × 10 9 nanodots cm –2 . The existence of a perovskite phase in the nanodots was confirmed by X-ray diffraction and X-ray photoelectron spectroscopy. The piezo-amplitude and ferroelectric domain response obtained from the nanodots, through piezoresponse force microscopy, confirmed the presence of ferroelectricity in the PZT arrays. Notably, PZT nanodots with a thickness ∼10 nm, which is close to the critical size limit of PZT, showed ferroelectric behavior. The presence of a multi-a/c domain structure in the nanodots was attributed to their polycrystalline nature.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Columnar grain growth in CSD films is usually caused by heterogeneous nucleation at the film-substrate interface.
“Columnar grain growth in CSD films is usually caused by heterogeneous nucleation at the film–substrate interface [34,35,36,37,38,39,40,41,42,43,44,45].”
From Control of Columnar Grain Microstructure in CSD LaNiO3 Films (2023) · cites this paper as [37]
Cited by
Sorted by citations
Control of Columnar Grain Microstructure in CSD LaNiO3 Films
Atanova, A. V., Seregin, D. S., Zhigalina, O. M., Khmelenin, D. N., Orlov, G. A., Turkina, D. I., Sigov, A. S., & Vorotilov, K. A. (2023) · Molecules · doi:10.3390/molecules28041938 · Cited by 5 · see citing works
- Authors
- Varghese, J., Ghoshal, T., Deepak, N., O’Regan, C., Whatmore, R. W., Morris, M. A., & Holmes, J. D.
- Affiliations
- Trinity College Dublin (IE)
- University College Cork (IE)
- Corresponding author
- Holmes, Justin D.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-28
- Volume
- 25
- Issue
- 8
- Pages
- 1458-1463
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W1977707603
- Cited by
- 34
- References
- 0
- Citations by year
- 2025: 1 · 2023: 3 · 2022: 6 · 2021: 4 · 2020: 1 · 2019: 5 · 2018: 3 · 2016: 5 · 2015: 3 · 2014: 3
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Chemistry of Materials (publishedVersion)
- Arrow@dit (Dublin Institute of Technology) (acceptedVersion)
- Cork Open Research Archive (University College Cork, Ireland) (submittedVersion)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
- Physical Sciences › Materials Science › Materials Chemistry › Block Copolymer Self-Assembly
- Physical Sciences › Engineering › Biomedical Engineering › Dielectric materials and actuators
- Keywords
- lead zirconate titanate, block copolymer self-assembly, polystyrene-block-poly(ethylene oxide), directed self-assembly, nanodot arrays, ferroelectricity, perovskite phase, piezoresponse, ferroelectric domains, polycrystalline thin films, critical thickness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review