Cited by 34Ferroelectric and Piezoelectric MaterialsBlock Copolymer Self-AssemblyDielectric materials and actuators

Fabrication of Arrays of Lead Zirconate Titanate (PZT) Nanodots via Block Copolymer Self-Assembly

Varghese, Justin, Ghoshal, Tandra, Deepak, Nitin, O’Regan, Colm, Whatmore, Roger W., Morris, Michael A., Holmes, Justin D.·2013·Chemistry of Materials

Abstract

This Article presents a simple methodology for the fabrication of two-dimensional arrays of lead zirconate titanate (PZT) nanodots on n-doped Si substrates via the directed self-assembly of PS- b -PEO block copolymer templates. The approach produces highly ordered PZT nanodot patterns, with lateral widths and heights as small as 20 and 10 nm, respectively, and a coverage density as high as ∼68 × 10 9 nanodots cm –2 . The existence of a perovskite phase in the nanodots was confirmed by X-ray diffraction and X-ray photoelectron spectroscopy. The piezo-amplitude and ferroelectric domain response obtained from the nanodots, through piezoresponse force microscopy, confirmed the presence of ferroelectricity in the PZT arrays. Notably, PZT nanodots with a thickness ∼10 nm, which is close to the critical size limit of PZT, showed ferroelectric behavior. The presence of a multi-a/c domain structure in the nanodots was attributed to their polycrystalline nature.

Integrity signals

Registry

Crossref · 10.1021/cm303759r

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Columnar grain growth in CSD films is usually caused by heterogeneous nucleation at the film-substrate interface.

    “Columnar grain growth in CSD films is usually caused by heterogeneous nucleation at the film–substrate interface [34,35,36,37,38,39,40,41,42,43,44,45].”

    From Control of Columnar Grain Microstructure in CSD LaNiO3 Films (2023) · cites this paper as [37]

Cited by

Sorted by citations

Authors
Varghese, J., Ghoshal, T., Deepak, N., O’Regan, C., Whatmore, R. W., Morris, M. A., & Holmes, J. D.
Affiliations
  • Trinity College Dublin (IE)
  • University College Cork (IE)
Corresponding author
Holmes, Justin D.
Venue
Chemistry of Materials
Published
2013-02-28
Volume
25
Issue
8
Pages
1458-1463
ISSN
  • 0897-4756 (ISSN-L)
  • 1520-5002
OpenAlex
W1977707603
Cited by
34
References
0
Citations by year
2025: 1 · 2023: 3 · 2022: 6 · 2021: 4 · 2020: 1 · 2019: 5 · 2018: 3 · 2016: 5 · 2015: 3 · 2014: 3
FWCI
1.65
Type
journal article
Language
en
Open access
closed
Locations
  • Chemistry of Materials (publishedVersion)
  • Arrow@dit (Dublin Institute of Technology) (acceptedVersion)
  • Cork Open Research Archive (University College Cork, Ireland) (submittedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Block Copolymer Self-Assembly
  • Physical Sciences › Engineering › Biomedical Engineering › Dielectric materials and actuators
Keywords
lead zirconate titanate, block copolymer self-assembly, polystyrene-block-poly(ethylene oxide), directed self-assembly, nanodot arrays, ferroelectricity, perovskite phase, piezoresponse, ferroelectric domains, polycrystalline thin films, critical thickness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review