The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Synthesis, Luminescence Properties, and Explosives Sensing with 1,1-Tetraphenylsilole- and 1,1-Silafluorene-vinylene Polymers
Abstract
The syntheses, spectroscopic characterizations, and fluorescence quenching efficiencies of polymers and copolymers containing tetraphenylsilole- or silafluorene-vinylene repeat units are reported. These materials were prepared by catalytic hydrosilylation reactions between appropriate monomeric metallole alkynes and hydrides. Trimeric model compounds methyl(tetraphenyl)silole-vinylene trimer ( 1 ), methyl(tetraphenyl)silole-silafluorene-vinylene cotrimer ( 2 ), and methylsilafluorene-vinylene trimer ( 3 ) were synthesized to provide detailed structural and spectroscopic characteristics of the polymer backbone and to assess the extent of delocalization in the luminescent excited state. Poly(tetraphenylsilole-vinylene) ( 4 ), poly(tetraphenylsilole-silafluorene-vinylene) ( 5 ), and poly(silafluorene-vinylene) ( 6 ) maintain a regio-regular trans -vinylene Si−C backbone with possible ground state σ*−π and excited state σ*−π* conjugation through the vinylene bridge between metallole units. Fluorescence spectra of the polymers show an ∼13 nm bathochromic shift in λ flu from their respective model compounds. Molecular weights ( M n ) for these polymers and copolymers are in the range of 4000–4500. Detection of nitroaromatic explosives by solution-phase fluorescence quenching of polymers 4 − 6 was observed with Stern−Volmer constants in the range of 400−20 000 for TNT, DNT, and picric acid (PA). A surface detection method for the analysis of solid particulates of TNT, DNT, PA, RDX, HMX, Tetryl, TNG, and PETN is also described for silafluorene-containing polymers. Polymer 6 exhibited detection for all the preceding types of explosive residues with a 200 pg cm −2 detection limit for Tetryl. Polymers 4 and 5 exhibited only luminescence quenching with nitroaromatic explosives, revealing that the excited-state energy of the sensor plays a key role in the fluorescence detection of explosives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density-functional thermochemistry. III. The role of exact exchange
Becke, A. D. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464913 · Cited by 103,767
Lee, C., Yang, W., & Parr, R. G. (1988) · Physical Review B · doi:10.1103/physrevb.37.785 · Cited by 100,874
The influence of polarization functions on molecular orbital hydrogenation energies
Hariharan, P. C., & Pople, J. A. (1973) · Theoretica Chimica Acta · doi:10.1007/bf00533485 · Cited by 15,816
Light-emitting diodes based on conjugated polymers
Burroughes, J. H., Bradley, D. D. C., Brown, A. R., Marks, R. N., Mackay, K., Friend, R. H., Burns, P. L., & Holmes, A. B. (1990) · Nature · doi:10.1038/347539a0 · Cited by 11,393
Electroluminescence in conjugated polymers
Friend, R. H., Gymer, R. W., Holmes, A. B., Burroughes, J. H., Marks, R. N., Taliani, C., Bradley, D. D. C., Santos, D. A. D., Brédas, J. L., Lögdlund, M., et al. (1999) · Nature · doi:10.1038/16393 · Cited by 5,977
Bauernschmitt, R., & Ahlrichs, R. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00440-x · Cited by 5,747
Stratmann, R. E., Scuseria, G. E., & Frisch, M. J. (1998) · The Journal of Chemical Physics · doi:10.1063/1.477483 · Cited by 5,099
Casida, M. E., Jamorski, C., Casida, K. C., & Salahub, D. R. (1998) · The Journal of Chemical Physics · doi:10.1063/1.475855 · Cited by 5,009
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Electroluminescent Conjugated Polymers—Seeing Polymers in a New Light
Kraft, A., Grimsdale, A. C., & Holmes, A. B. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980302)37:4<402::aid-anie402>3.0.co;2-9 · Cited by 3,124
Management of singlet and triplet excitons for efficient white organic light-emitting devices
Sun, Y., Giebink, N. C., Kanno, H., Ma, B., Thompson, M. E., & Forrest, S. R. (2006) · Nature · doi:10.1038/nature04645 · Cited by 2,327
Chen, J., Law, C. C. W., Lam, J. W. Y., Dong, Y., Lo, S. M. F., Williams, I. D., Zhu, D., & Tang, B. Z. (2003) · Chemistry of Materials · doi:10.1021/cm021715z · Cited by 1,190
Polymer sensors for nitroaromatic explosives detection
Toal, S. J., & Trogler, W. C. (2006) · Journal of Materials Chemistry · doi:10.1039/b517953j · Cited by 998
Self-citationPorous Shape Persistent Fluorescent Polymer Films: An Approach to TNT Sensory Materials
Yang, J.-S., & Swager, T. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja9742996 · Cited by 767
Relationship between the ionization and oxidation potentials of molecular organic semiconductors
DANDRADE, B., DATTA, S., FORREST, S., DJUROVICH, P., POLIKARPOV, E., & THOMPSON, M. (2005) · Organic Electronics · doi:10.1016/j.orgel.2005.01.002 · Cited by 742
Zhou, Q., & Swager, T. M. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00155a023 · Cited by 690
Detection of Nitroaromatic Explosives Based on Photoluminescent Polymers Containing Metalloles
Sohn, H., Sailor, M. J., Magde, D., & Trogler, W. C. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021214e · Cited by 673
Self-citationEfficient blue emission from siloles
Tang, B. Z., Zhan, X., Yu, G., Lee, P. P. S., Liu, Y., & Zhu, D. (2001) · Journal of Materials Chemistry · doi:10.1039/b102221k · Cited by 658
Sylvia, J. M., Janni, J. A., Klein, J. D., & Spencer, K. M. (2000) · Analytical Chemistry · doi:10.1021/ac0006573 · Cited by 613
Ultrahigh Energy Gap Hosts in Deep Blue Organic Electrophosphorescent Devices
Ren, X., Li, J., Holmes, R. J., Djurovich, P. I., Forrest, S. R., & Thompson, M. E. (2004) · Chemistry of Materials · doi:10.1021/cm049402m · Cited by 487
Silole Derivatives as Efficient Electron Transporting Materials
Tamao, K., Uchida, M., Izumizawa, T., Furukawa, K., & Yamaguchi, S. (1996) · Journal of the American Chemical Society · doi:10.1021/ja962829c · Cited by 444
EXPLOSIVES DETECTION: A Challenge for Physical Chemistry
Steinfeld, J. I., & Wormhoudt, J. (1998) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.49.1.203 · Cited by 413
Ren, Y., Lam, J. W. Y., Dong, Y., Tang, B. Z., & Wong, K. S. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp046659z · Cited by 339
Luminescent Silole Nanoparticles as Chemoselective Sensors for Cr(VI)
Toal, S. J., Jones, K. A., Magde, D., & Trogler, W. C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052582w · Cited by 328
Self-citationFluorescence Studies of Poly(p-phenyleneethynylene)s: The Effect of Anthracene Substitution
Swager, T. M., Gil, C. J., & Wrighton, M. S. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100014a003 · Cited by 307
Detection of TNT and Picric Acid on Surfaces and in Seawater by Using Photoluminescent Polysiloles
Sohn, H., Calhoun, R. M., Sailor, M. J., & Trogler, W. C. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010601)40:11<2104::aid-anie2104>3.0.co;2-# · Cited by 281
Self-citationYamaguchi, S., Endo, T., Uchida, M., Izumizawa, T., Furukawa, K., & Tamao, K. (2000) · Chemistry – A European Journal · doi:10.1002/(sici)1521-3765(20000502)6:9<1683::aid-chem1683>3.0.co;2-m · Cited by 225
Thomas III, S. W., Amara, J. P., Bjork, R. E., & Swager, T. M. (2005) · Chemical Communications · doi:10.1039/b508408c · Cited by 206
Highly Fluorescent Solid-State Asymmetric Spirosilabifluorene Derivatives
Lee, S. H., Jang, B.-B., & Kafafi, Z. H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042762q · Cited by 192
Fluorescent Polyacetylene Thin Film Sensor for Nitroaromatics
Liu, Y., Mills, R. C., Boncella, J. M., & Schanze, K. S. (2001) · Langmuir · doi:10.1021/la010696p · Cited by 170
Luminescent oligo(tetraphenyl)silole nanoparticles as chemical sensors for aqueous TNT
Toal, S. J., Magde, D., & Trogler, W. C. (2005) · Chemical Communications · doi:10.1039/b509404f · Cited by 156
Self-citationDeng, L. Q., Furuta, P. T., Garon, S., et al. (2005) · Chemistry of Materials · doi:10.1021/cm051922+ · Cited by 141
Fluorescent conjugated polymer films as TNT chemosensors
Chang, C.-P., Chao, C.-Y., Huang, J. H., Li, A.-K., Hsu, C., Lin, M., Hsieh, B. R., & Su, A.-C. (2004) · Synthetic Metals · doi:10.1016/j.synthmet.2004.04.003 · Cited by 136
An Electroluminescent Polysilole and Some Dichlorooligosiloles
Sohn, H., Huddleston, R. R., Powell, D. R., West, R., Oka, K., & Xu, Y. (1999) · Journal of the American Chemical Society · doi:10.1021/ja983350i · Cited by 119
Soluble poly(1,4‐phenyleneethynylene)s
Giesa, R., & Schulz, R. C. (1990) · Die Makromolekulare Chemie · doi:10.1002/macp.1990.021910413 · Cited by 103
Voltammetric determination of nitroaromatic and nitramine explosives contamination in soil
PONSARAVANAN, N., Venugopalan, S., Senthilkumar, N., Santhosh, P., Kavita, B., & Prabu, H. G. (2005) · Talanta · doi:10.1016/j.talanta.2005.10.041 · Cited by 95
Geramita, K., McBee, J. L., Shen, Y., Radu, N. S., & Tilley, T. D. (2006) · Chemistry of Materials · doi:10.1021/cm060346u · Cited by 73
Light-Emitting Characteristics of Conjugated Polymers
Shim, H., & Jin, J. (2007) · Springer eBooks · doi:10.1007/3-540-44608-7_4 · Cited by 71
Toal, S. J., Sanchez, J. C., Dugan, R. E., & Trogler, W. C. (2006) · Journal of Forensic Sciences · doi:10.1111/j.1556-4029.2006.00332.x · Cited by 70
Self-citationThe refractive index correction to the radiative rate constant in fluorescence lifetime measurements
Lampert, R. A., Meech, S. R., Metcalfe, J., et al. (1983) · Chemical Physics Letters · doi:10.1016/0009-2614(83)87560-5 · Cited by 67
Kolla, P. (1995) · Analytical Chemistry · doi:10.1021/ac00101a722 · Cited by 38
Cited by
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Highly Selective Detection of Nitro Explosives by a Luminescent Metal–Organic Framework
Nagarkar, S. S., Joarder, B., Chaudhari, A. K., Mukherjee, S., & Ghosh, S. K. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201208885 · Cited by 1,353
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Acetylenic Polymers: Syntheses, Structures, and Functions
Liu, J., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Reviews · doi:10.1021/cr900149d · Cited by 1,196
Optical chemosensors and reagents to detect explosives
Salinas, Y., Martínez-Máñez, R., Marcos, M. D., Sancenón, F., Costero, A. M., Parra, M., & Gil, S. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15173h · Cited by 1,144
Metadata
- Authors
- Sanchez, J. C., DiPasquale, A. G., Rheingold, A. L., & Trogler, W. C.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-11-21
- Volume
- 19
- Issue
- 26
- Pages
- 6459-6470
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W1977308064
- Cited by
- 303
- References
- 41
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.