Polymer Microbubbles As Diagnostic and Therapeutic Gas Delivery Device
The DOI matches its Crossref record.
Abstract
Nitric oxide plays a central role in controlling arterial thrombosis and in cardiovascular diseases by inhibiting the platelet aggregation process. This process is regulated by giving a deactivating signal for the protein membrane integrins, the major platelet adhesion receptors. The localized production of NO, naturally occurring in arterial vessels, is carried out by the NO synthase enzymatic system. Inhibition of platelets aggregation in the coagulation cascade process is due to the antagonist action of NO toward integrin-fibrinogen induced platelet adhesion. However, sometimes the natural supply of NO is not sufficient to prevent clotting. The design of devices for suitable transport and delivery of NO is therefore important. We are developing a new concept of drug delivery in which NO release can be performed by means of polymer shelled microbubbles. The NO release can theoretically be concentrated in vessels with acute thrombosis by bursting of the microparticles upon insonification. This feature is linked to the structural and mechanical properties of the particles shell and it would make minimally invasive local theraphy of acute vascular disease feasible. In this paper, we present a study on some new structural and mechanical features of this microdevice supporting its NO loading capacity and in vitro efficacy in preventing the formation of a clot by releasing NO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nitric oxide release: Part I. Macromolecular scaffolds
Riccio, D. A., & Schoenfisch, M. H. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15272j · Cited by 475
Wo, Y., Brisbois, E. J., Bartlett, R. H., & Meyerhoff, M. E. (2016) · Biomaterials Science · doi:10.1039/c6bm00271d · Cited by 251
Duan, L., Yang, L., Jin, J., Yang, F., Liu, D., Hu, K., Wang, Q., Yue, Y., & Gu, N. (2020) · Theranostics · doi:10.7150/thno.37593 · Cited by 251
“Recently, bioactive gases that have significant therapeutic potential, including nitric oxide [94, 95] and oxygen [96, 97]; have been encapsulated in UCAs for parenteral delivery.”
BackgroundStimuli-responsive nanobubbles for biomedical applications
Xiong, R., Xu, R. X., Huang, C., De Smedt, S., & Braeckmans, K. (2021) · Chemical Society Reviews · doi:10.1039/c9cs00839j · Cited by 236
Polymer‐Based Nitric Oxide Therapies: Recent Insights for Biomedical Applications
Jen, M. C., Serrano, M. C., van Lith, R., & Ameer, G. A. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101707 · Cited by 194
Recent advances in theranostic polymeric nanoparticles for cancer treatment: A review
Indoria, S., Singh, V., & Hsieh, M.-F. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119314 · Cited by 168
Microcapsule mechanics: From stability to function
Neubauer, M. P., Poehlmann, M., & Fery, A. (2014) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2013.11.016 · Cited by 165
Liu, Z., Lammers, T., Ehling, J., Fokong, S., Bornemann, J., Kiessling, F., & Gätjens, J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.019 · Cited by 158
Metadata
- Authors
- Cavalieri, F., Finelli, I., Tortora, M., Mozetic, P., Chiessi, E., Polizio, F., Brismar, T. B., & Paradossi, G.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-04-15
- Volume
- 20
- Issue
- 10
- Pages
- 3254-3258
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W1994333385
- Cited by
- 80
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.