The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Resonance Imaging Contrast Agents Based on Iron Oxide Superparamagnetic Ferrofluids
Abstract
Novel systems based on suspensions of colloidal magnetic nanoparticles have been investigated as perspective superparamagnetic contrast agents (CA) for magnetic resonance imaging (MRI). The nanostructures that we have studied contain surfactant-capped magnetite (Fe 3 O 4 ) inorganic cores with different controlled sizes, ranging from 5.5 to 12 nm. The as-synthesized nanostructures are passivated by hydrophobic surfactants and thus are fully dispersible in nonpolar media. The magnetic nanocrystals have been transferred into aqueous media by a procedure based on the surface intercalation and coating with an amphiphilic polymer shell. The MRI efficiency in contrasting images, i.e., the NMR relaxivities r 1 and r 2, have been compared with Endorem and Sinerem, commercial superparamagnetic MRI contrast agents. We found that our nanostructures exhibit r 1 and r 2 relaxivities comparable to those of commercial CA over the whole frequency range. The MRI efficiency of our samples was related to their microstructural and magnetic properties. The transverse relaxivity r 2, leading the contrast in “negative” superparamagnetic agents, was found to improve as the diameter of the inorganic core is increased. The NMR relaxometry profile confirmed the nature of the physical mechanisms inducing the increase of the nuclear relaxation rates at low (magnetic anisotropy) and high (Curie relaxation) fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Cited by
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Self-citationFundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Hühn, J., Carrillo-Carrion, C., Soliman, M. G., Pfeiffer, C., Valdeperez, D., Masood, A., Chakraborty, I., Zhu, L., Gallego, M., Yue, Z., et al. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.6b04738 · Cited by 283
Self-citation
Metadata
- Authors
- Casula, M. F., Floris, P., Innocenti, C., Lascialfari, A., Marinone, M., Corti, M., Sperling, R. A., Parak, W. J., & Sangregorio, C.
- Venue
- Chemistry of Materials
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-19
- Volume
- 22
- Issue
- 5
- Pages
- 1739-1748
- ISSN
- 0897-4756 (ISSN-L)
- 1520-5002
- OpenAlex
- W2075829430
- Cited by
- 162
- References
- 1
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging Contrast Agents Based on Iron Oxide Superparamagnetic Ferrofluids. https://app.cochat.ai/papers/10.1021/cm9031557
- The paper
- Casula, M. F., Floris, P., Innocenti, C., Lascialfari, A., Marinone, M., Corti, M., Sperling, R. A., Parak, W. J., & Sangregorio, C. (2010). Magnetic Resonance Imaging Contrast Agents Based on Iron Oxide Superparamagnetic Ferrofluids. Chemistry of Materials. https://doi.org/10.1021/cm9031557
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.