Optical Tweezers Analysis of DNA–Protein Complexes
The DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.
Abstract
Optical tweezers have grown to be one of the most powerful and versatile single-molecule methods for analysis of DNA-protein complexes. The power of optical tweezers lies primarily in its extremely high sensitivity and bandwidth in combination with a wide and biologically relevant force range. To accurately apply and measure a force in an optical tweezers assay, the biological system, a DNA molecule, is tethered on two opposite ends. Most commonly used are the single-beam and dual-beam force measuring optical tweezers. Extreme refinement of optical tweezers sensitivity has led to unprecedented mechanistic insight into the single-base-pair stepping of RNA polymerases during DNA transcription. Experiments on DNA repair, which involves the orchestrated action of many proteins, each with different physical characteristics, have showcased the versatility of optical tweezers assays and also illustrated the large advantages of concurrent visualization by fluorescence microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030
Acceleration and Trapping of Particles by Radiation Pressure
Ashkin, A. (1970) · Physical Review Letters · doi:10.1103/physrevlett.24.156 · Cited by 5,013
Smith, S. B., Cui, Y., & Bustamante, C. (1996) · Science · doi:10.1126/science.271.5250.795 · Cited by 2,770
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Marko, J. F., & Siggia, E. D. (1995) · Macromolecules · doi:10.1021/ma00130a008 · Cited by 2,307
Neuman, K. C., & Block, S. M. (2004) · Review of Scientific Instruments · doi:10.1063/1.1785844 · Cited by 2,165
Probing the Relation Between Force—Lifetime—and Chemistry in Single Molecular Bonds
Evans, E. (2001) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.30.1.105 · Cited by 1,325
Recent Advances in Optical Tweezers
Moffitt, J. R., Chemla, Y. R., Smith, S. B., & Bustamante, C. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.043007.090225 · Cited by 1,084
The bacteriophage φ29 portal motor can package DNA against a large internal force
Smith, D. E., Tans, S. J., Smith, S. B., Grimes, S., Anderson, D. L., & Bustamante, C. (2001) · Nature · doi:10.1038/35099581 · Cited by 1,032
Microscopy and its focal switch
Hell, S. W. (2009) · Nature Methods · doi:10.1038/nmeth.1291 · Cited by 986
Cited by
Optical tweezers in single-molecule biophysics
Bustamante, C. J., Chemla, Y. R., Liu, S., & Wang, M. D. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00021-6 · Cited by 615
Sliding sleeves of XRCC4–XLF bridge DNA and connect fragments of broken DNA
Brouwer, I., Sitters, G., Candelli, A., Heerema, S. J., Heller, I., Melo de, A. J., Zhang, H., Normanno, D., Modesti, M., Peterman, E. J. G., et al. (2016) · Nature · doi:10.1038/nature18643 · Cited by 166
Self-citationDNA polymerase actively and sequentially displaces single-stranded DNA-binding proteins
Xu, L., Jin, S., Urem, M., Lee, S.-J., Lamers, M. H., Chen, X., Wolynes, P. G., & Wuite, G. J. L. (2025) · Nature Communications · doi:10.1038/s41467-025-62531-1 · Cited by 3
Self-citation
Metadata
- Authors
- Heller, I., Hoekstra, T. P., King, G. A., Peterman, E. J. G., & Wuite, G. J. L.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-21
- Volume
- 114
- Issue
- 6
- Pages
- 3087-3119
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2332486941
- Cited by
- 212
- References
- 133
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.