Cited by 224Advanced biosensing and bioanalysis techniquesPhotonic Crystals and ApplicationsPhotochromic and Fluorescence Chemistry

Holographic Sensors: Three-Dimensional Analyte-Sensitive Nanostructures and Their Applications

Open access
Yetisen, Ali K., Naydenova, Izabela, da Cruz Vasconcellos, Fernando, Blyth, Jeffrey, Lowe, Christopher R.·2014·Chemical Reviews

Abstract

Holographic sensors are analytical devices that systematically diffract narrow-band light in the ultraviolet to near-infrared range for application in the detection and quantification of analytes and/or physical parameters. They can be functionalized with analyte-responsive materials to construct highly sensitive optical sensors for use in testing, where a visual readout, fast turnaround time, and reversibility are needed. Holography allows fabrication of disposable sensors that are lightweight for miniaturization and multiplexing purposes.3 Holographic sensors offer three capabilities on a single analytical device: (i) label-free analyte-responsive polymer, (ii) real-time, reversible quantification of the external stimuli, and (iii) three-dimensional visual image display.

Integrity signals

Registry

Crossref · 10.1021/cr500116a

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Microfluidic contact lenses may allow sampling tear fluid for multiplexed sensing in vivo and they may simultaneously deliver drugs to the eye.

    “Microfluidic contact lenses may allow sampling tear fluid for multiplexed sensing in vivo and they may simultaneously deliver drugs to the eye.80”

    From Wearables in Medicine (2018) · cites this paper as [80]

  • The microfluidic channel diameters ranged from 100 to 150 μm and their stability properties were evaluated by flow testing of artificial fluid.

    “The microfluidic channel diameters ranged from 100 to 150 µm and their stability properties were evaluated by flow testing of artificial fluid.”

    From Wearables in Medicine (2018) · cites this paper as [80]

  • Microfluidic contact lenses have been fabricated by laser ablation and fiber templating.

    “Microfluidic contact lenses have been fabricated by laser ablation and fiber templating.”

    From Wearables in Medicine (2018) · cites this paper as [80]

  • Microfluidic contact lenses were also functionalized with fluorophores to demonstrate their optical emission capabilities in the visible spectrum.

    “Microfluidic contact lenses were also functionalized with fluorophores to demonstrate their optical emission capabilities in the visible spectrum.”

    From Wearables in Medicine (2018) · cites this paper as [80]

  • A microlithography method has been developed to create microconcavities and microchannels in contact lenses.

    “A microlithography method has been developed to create microconcavities and microchannels in contact lenses.80”

    From Wearables in Medicine (2018) · cites this paper as [80]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yetisen, A. K., Naydenova, I., da Cruz Vasconcellos, F., Blyth, J., & Lowe, C. R.
Affiliations
  • University of Cambridge (GB)
  • Dublin Institute of Technology (IE)
  • University of Cambridge , , Tennis Court Road , ,
Venue
Chemical Reviews
Published
2014-09-11
Volume
114
Issue
20
Pages
10654-10696
ISSN
  • 0009-2665 (ISSN-L)
  • 1520-6890
OpenAlex
W2060577038
Cited by
224
References
5
Citations by year
2026: 13 · 2025: 21 · 2024: 20 · 2023: 14 · 2022: 17 · 2021: 15 · 2020: 12 · 2019: 19 · 2018: 20 · 2017: 17 · 2016: 29 · 2015: 17 · 2014: 10
FWCI
2.29
Type
journal article
Language
en
Open access
Locations
  • Chemical Reviews (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion, cc-by-nc-sa)
  • Arrow - TU Dublin (Technological University Dublin) (submittedVersion)
  • Arrow - TU Dublin (Technological University Dublin) (submittedVersion, cc-by-nc-sa)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photonic Crystals and Applications
  • Physical Sciences › Materials Science › Materials Chemistry › Photochromic and Fluorescence Chemistry
Keywords
holographic sensors, diffraction gratings, label-free detection, optical sensors, three-dimensional nanostructures, visual readout, disposable sensors, sensor miniaturization, multiplexed sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review