The DOI matches its Crossref record.
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTCarrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical SensorsPhilippe Bühlmann, Ernö Pretsch, and Eric BakkerView Author Information Department of Chemistry, School of Science, The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-0033, Japan, Department of Organic Chemistry, Swiss Federal Institute of Technology (ETH), Universitätstrasse 16, CH-8092 Zürich, Switzerland, and Department of Chemistry, Auburn University, Auburn, Alabama 36849 Cite this: Chem. Rev. 1998, 98, 4, 1593–1688Publication Date (Web):June 4, 1998Publication History Received29 December 1997Revised8 April 1998Published online4 June 1998Published inissue 1 June 1998https://doi.org/10.1021/cr970113+Copyright © 1998 American Chemical SocietyRIGHTS & PERMISSIONSArticle Views8347Altmetric-Citations1490LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InReddit Read OnlinePDF (3 MB) Get e-AlertsSUBJECTS:Electrodes,Ions,Membranes,Selectivity,Sensors Get e-Alerts
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Electrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
Gupta, V. K., Ganjali, M. R., Norouzi, P., Khani, H., Nayak, A., & Agarwal, S. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.589773 · Cited by 580
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Ionophore-Based SERS Sensing for Electrolyte Cations
Grewal, U., Ricca, J. G., Zhang, L., Khan, M. D. H., West, L. M., Terentis, A. C., & Wang, R. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c03733 · Cited by 7
Metadata
- Authors
- Bühlmann, P., Pretsch, E., & Bakker, E.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-06-01
- Volume
- 98
- Issue
- 4
- Pages
- 1593-1688
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2082405251
- Cited by
- 1,859
- References
- 0
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. https://app.cochat.ai/papers/10.1021/cr970113+
- The paper
- Bühlmann, P., Pretsch, E., & Bakker, E. (1998). Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. Chemical Reviews. https://doi.org/10.1021/cr970113%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.