CO2 Sequestration by Direct Gas−Solid Carbonation of Air Pollution Control (APC) Residues
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Direct gas−solid carbonation of alkaline residues from air pollution control (APC) systems was investigated with the aim of evaluating its contribution as a CO 2 storage option as well as its effect on the properties of the residues, namely, the leaching behavior, which may affect the strategies for their disposal or reuse. APC residues from a medical solid-waste incinerator located in the vicinity of Rome, Italy, were selected for performing carbonation experiments with pure CO 2 at reaction temperatures in the 200−500 °C range. The extent of calcium conversion to the carbonate form was found to be negligible below 300 °C, whereas the maximum conversion of 57% was already measured at 400 °C. This implies a storage capacity of 0.12 kg of CO 2 /kg of dry solid. Considering that the APC residues production in the EU25 equals 1260 kiloton/year, this translates in a CO 2 storage potential for the European market of 0.15 megatons of CO 2 /year. On the basis of the ENV 12457-2 leaching test procedure performed after accelerated carbonation, the concentrations of Cd, Cu, and Cr in the leachate were below the limits imposed by the Italian regulation for disposal in nonhazardous waste landfills, whereas only the lead concentration still exceeded the corresponding limit value. These results indicate that accelerated carbonation of alkaline residues could be suitable to address the issue of CO 2 storage, especially for niche applications such as at steel plants and solid-waste incinerators, where both the residues and the CO 2 are present.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using CaO- and MgO-rich industrial waste streams for carbon sequestration
Stolaroff, J. K., Lowry, G. V., & Keith, D. W. (2005) · Energy Conversion and Management · doi:10.1016/j.enconman.2004.05.009 · Cited by 224
Fernández Bertos, M., Li, X., Simons, S. J. R., Hills, C. D., & Carey, P. J. (2004) · Green Chem. · doi:10.1039/b401872a · Cited by 208
Cited by
A review of mineral carbonation technologies to sequester CO 2
Sanna, A., Uibu, M., Caramanna, G., Kuusik, R., & Maroto-Valer, M. M. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00035h · Cited by 1,258
Hanifa, M., Agarwal, R., Sharma, U., Thapliyal, P. C., & Singh, L. P. (2023) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2022.102292 · Cited by 372
(2008) · Cited by 201
Waste materials for carbon capture and storage by mineralisation (CCSM)–A UK perspective
Sanna, A., Dri, M., Hall, M. R., & Maroto-Valer, M. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.06.049 · Cited by 159
Polettini, A., Pomi, R., & Stramazzo, A. (2016) · Journal of Environmental Management · doi:10.1016/j.jenvman.2015.11.042 · Cited by 151
Self-citation
Metadata
- Authors
- Baciocchi, R., Polettini, A., Pomi, R., Prigiobbe, V., Von Zedwitz, V. N., & Steinfeld, A.
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-07
- Volume
- 20
- Issue
- 5
- Pages
- 1933-1940
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- OpenAlex
- W2085929948
- Cited by
- 83
- References
- 2
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.