Carbonation and Hydration Characteristics of Dry Potassium-Based Sorbents for CO2 Capture
The DOI matches its Crossref record.
Abstract
Thermogravimetric apparatus (TGA) and X-ray diffraction (XRD) have been used to study the characteristics of potassium-based sorbents for CO 2 capture. The carbonation reactivity of K 2 CO 3 ·1.5H 2 O and K 2 CO 3 dehydrated from K 2 CO 3 ·1.5H 2 O was weak. However, K 2 CO 3 calcined from KHCO 3 showed excellent carbonation capacity and no deactivation of sorbents during multiple cycles. The XRD results showed that the sample dehydrated from K 2 CO 3 ·1.5H 2 O was K 2 CO 3 with structure of monoclinic crystal (PC#1). The carbonation products of PC#1 included K 2 CO 3 ·1.5H 2 O and KHCO 3, and K 2 CO 3 ·1.5H 2 O was the main product. Correspondingly, K 2 CO 3 with structure of hexagonal crystal (PC#2) was the product calcined from KHCO 3, and the main carbonation product of PC#2 was KHCO 3 . The byproduct of K 4 H 2 (CO 3 ) 3 ·1.5H 2 O for PC#2 would affect the carbonation processes. Hydration tests confirmed the two hypotheses: the hydration reaction will first occur for K 2 CO 3 with structure of monoclinic crystal, and the carbonation reaction will first occur for K 2 CO 3 with structure of hexagonal crystal. The reaction principles were analyzed by product and the relevant reactions. This investigation can be used as basic data for dry potassium-based sorbents capturing CO 2 from flue gas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Post-Combustion CO 2 Capture Using Solid Sorbents: A Review
Samanta, A., Zhao, A., Shimizu, G. K. H., Sarkar, P., & Gupta, R. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie200686q · Cited by 1,889
CO2 capture by solid adsorbents and their applications: current status and new trends
Wang, Q., Luo, J., Zhong, Z., & Borgna, A. (2011) · Energy Environ. Sci. · doi:10.1039/c0ee00064g · Cited by 1,611
A review on solid adsorbents for carbon dioxide capture
Lee, S.-Y., & Park, S.-J. (2015) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2014.09.001 · Cited by 707
Li, L., Zhao, N., Wei, W., & Sun, Y. (2013) · Fuel · doi:10.1016/j.fuel.2011.08.022 · Cited by 480
Catalytic effects of potassium on biomass pyrolysis, combustion and torrefaction
Safar, M., Lin, B.-J., Chen, W.-H., Langauer, D., Chang, J.-S., Raclavska, H., Pétrissans, A., Rousset, P., & Pétrissans, M. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.10.065 · Cited by 273
Salaudeen, S. A., Acharya, B., & Dutta, A. (2018) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2017.11.012 · Cited by 253
Direct CO2 capture from ambient air using K2CO3/Al2O3 composite sorbent
Veselovskaya, J. V., Derevschikov, V. S., Kardash, T. Y., Stonkus, O. A., Trubitsina, T. A., & Okunev, A. G. (2013) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2013.05.006 · Cited by 161
Metadata
- Authors
- Zhao, C., Chen, X., Zhao, C., & Liu, Y.
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-06
- Volume
- 23
- Issue
- 3
- Pages
- 1766-1769
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- OpenAlex
- W1974159431
- Cited by
- 103
- References
- 0
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.