The DOI matches its Crossref record.
Use of CaMn0.875Ti0.125O3as Oxygen Carrier in Chemical-Looping with Oxygen Uncoupling
Abstract
Chemical-looping with oxygen uncoupling (CLOU) is a novel method to burn fuels in gas-phase oxygen without the need for an energy-intensive air separation unit. The carbon dioxide from the combustion is obtained separated from the nitrogen in the combustion air. The technique is based on chemical-looping combustion (CLC) but does not involve any direct reaction between the fuel and oxygen carrier. Instead, the CLOU process uses three steps in two reactors, one air reactor where a metal oxide captures oxygen from the combustion air (step 1), and a fuel reactor where the metal oxide releases oxygen (step 2) and where this oxygen reacts with a fuel (step 3). This means that the fuel burns directly with gaseous O 2 . In this work CaMn 0.875 Ti 0.125 O 3 will be used as oxygen carrier. Experiments were first performed with a thermogravimetric analyzer (TGA). Here the sintering temperature, and thereby the porosity, for the produced granulates was varied and optimized. The substitution of Ti on Mn sites in CaMnO 3 was chosen since this material showed no coke formation even in dry CH 4 at high temperatures. This was followed by fluidized bed experiments with both methane and petroleum coke as fuel. The CaMn 0.875 Ti 0.125 O 3 particles showed promising results both for the tests performed in TGA and in fluidized bed experiments. CaMn 0.875 Ti 0.125 O 3 released O 2 both in inert and reducing atmosphere, making it a possible candidate as oxygen carrier in CLOU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Progress in Chemical-Looping Combustion and Reforming technologies
Adanez, J., Abad, A., Garcia-Labiano, F., Gayan, P., & de Diego, L. F. (2012) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2011.09.001 · Cited by 2,230
Chemical looping combustion of solid fuels
Adánez, J., Abad, A., Mendiara, T., Gayán, P., de Diego, L. F., & García-Labiano, F. (2018) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2017.07.005 · Cited by 612
Biomass-based chemical looping technologies: the good, the bad and the future
Zhao, X., Zhou, H., Sikarwar, V. S., Zhao, M., Park, A.-H. A., Fennell, P. S., Shen, L., & Fan, L.-S. (2017) · Energy & Environmental Science · doi:10.1039/c6ee03718f · Cited by 558
Arandiyan, H., S. Mofarah, S., Sorrell, C. C., Doustkhah, E., Sajjadi, B., Hao, D., Wang, Y., Sun, H., Ni, B.-J., Rezaei, M., et al. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00639d · Cited by 337
Present status and overview of Chemical Looping Combustion technology
Nandy, A., Loha, C., Gu, S., Sarkar, P., Karmakar, M. K., & Chatterjee, P. K. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.003 · Cited by 275
Abad, A., Adánez-Rubio, I., Gayán, P., García-Labiano, F., de Diego, L. F., & Adánez, J. (2012) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2011.10.016 · Cited by 262
Metadata
- Authors
- Leion, H., Larring, Y., Bakken, E., Bredesen, R., Mattisson, T., & Lyngfelt, A.
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-10-15
- Volume
- 23
- Issue
- 10
- Pages
- 5276-5283
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- OpenAlex
- W2079153880
- Cited by
- 164
- References
- 0
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.