Hot Gas Cleaning and Upgrading with a Calcined Dolomite Located Downstream a Biomass Fluidized Bed Gasifier Operating with Steam−Oxygen Mixtures
The DOI matches its Crossref record.
Abstract
Cleaning and upgrading of the hot raw gas from a biomass gasifier, bubbling fluidized bed type, is studied at small pilot plant scale (10 kg biomass fed/h) using a calcined dolomite located downstream from the gasifier. Gasification is made with steam−oxygen mixtures at 800−850 °C and atmospheric pressure. Main variables studied are the gas residence time in the bed of dolomite and the gas atmosphere composition, which depends on the gasifying agent (H 2 O + O 2 )-to-biomass and H 2 O/O 2 ratios. H 2 and CO content in the flue gas increases by 16−23 vol % and decreases by 15−22 vol % (dry basis), respectively. Although CH 4 conversion (elimination) higher than 30 vol % has never been reached, tar conversion (elimination) of 90−95 vol % are obtained with space times of 0.06−0.15 kg calcined dolomite h - 1 m - 3 . A detailed study is here presented on how the calcined dolomite significantly cleans and upgrades the flue gas, increasing also the gas yield by 0.15−0.40 m 3 (STP)/kg daf biomass fed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of literature on catalysts for biomass gasification
Sutton, D., Kelleher, B., & Ross, J. R. H. (2001) · Fuel Processing Technology · doi:10.1016/s0378-3820(01)00208-9 · Cited by 1,178
Biomass Gasifier ''Tars'': Their Nature, Formation, and Conversion
Milne, T. A., Evans, R. J., & Abatzaglou, N. (1998) · doi:10.2172/3726 · Cited by 1,031
Tar reduction in biomass producer gas via mechanical, catalytic and thermal methods: A review
Anis, S., & Zainal, Z. A. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.02.018 · Cited by 802
Recent progresses in catalytic tar elimination during biomass gasification or pyrolysis—A review
Shen, Y., & Yoshikawa, K. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.12.062 · Cited by 561
A review on biomass gasification syngas cleanup
Abdoulmoumine, N., Adhikari, S., Kulkarni, A., & Chattanathan, S. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.05.095 · Cited by 476
Metadata
- Authors
- Pérez, P., Aznar, P. M., Caballero, M. A., Gil, J., Martín, J. A., & Corella, J.
- Venue
- Energy & Fuels
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-11-01
- Volume
- 11
- Issue
- 6
- Pages
- 1194-1203
- ISSN
- 0887-0624 (ISSN-L)
- 1520-5029
- OpenAlex
- W2032589610
- Cited by
- 121
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hot Gas Cleaning and Upgrading with a Calcined Dolomite Located Downstream a Biomass Fluidized Bed Gasifier Operating with Steam−Oxygen Mixtures. https://app.cochat.ai/papers/10.1021/ef970046m
- The paper
- Pérez, P., Aznar, P. M., Caballero, M. A., Gil, J., Martín, J. A., & Corella, J. (1997). Hot Gas Cleaning and Upgrading with a Calcined Dolomite Located Downstream a Biomass Fluidized Bed Gasifier Operating with Steam−Oxygen Mixtures. Energy & Fuels. https://doi.org/10.1021/ef970046m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.