CoChat

Characteristics of Chars Prepared from Various Pulverized Coals at Different Temperatures Using Drop-Tube Furnace

Lu, Liming, Sahajwalla, Veena, Harris, David · 2000 · Energy & Fuels
Cited by 122

The DOI matches its Crossref record.

Abstract

Char samples were prepared from five Australian black coals at different temperatures using a well-characterized drop-tube furnace. The characteristics of resultant chars and their parent coals were determined by such techniques as chemical analysis, XRD (X-ray diffraction), FESEM (field emission scanning electron microscopy), and the newly developed FIB (focused ion beam) miller. Some conventional particle analysis techniques were also used. The atomic structure, physical structure, and chemistry of chars were investigated as a function of pyrolysis conditions including pyrolysis temperature and coal type. Pyrolysis temperature is one of the key parameters influencing the char atomic structure. In general, the chars become more ordered and condensed with increasing pyrolysis temperature. This could be seen in their crystallite size ( L 11 ), aromaticity ( f a ), and interlayer spacing ( d 002 / d γ ). After being treated at 1200 °C, the L 11 value increased from 5.9−6.5 Å for raw coals to 7.8−10 Å for the chars, and f a increased from 58−72% for raw coals to 75−82% for chars. Meanwhile d 002 decreased from 3.5−3.59 Å for raw coals to 3.46−3.53 Å for chars, and d γ decreased upon charring from 4.72−5.01 to 4.33−4.74 Å. The char atomic structure is also dependent on coal type. However, the strong dependence on volatile matter observed for raw coals is diminished for the chars. Although all chars, except chars from coal AC-5, have similar spherical morphologies and surface areas, chars from different coals demonstrate extremely different pore structure. Some chars are very porous and light, while the others are solid and dense. The chemical analysis of chars shows that the atomic ratios H/C and O/C significantly decrease with increasing pyrolysis temperature. At pyrolysis temperatures of 1200 °C or greater, all the obtained chars have similar H/C and O/C ratios regardless of their origins. The decrease in H/C ratio is in agreement with the disappearance of γ band and increasing aromaticity, which were observed in char XRD spectra with increasing pyrolysis temperature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ef990236s

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Lu, L., Sahajwalla, V., & Harris, D.
Venue
Energy & Fuels
Published
2000-05-05
Volume
14
Issue
4
Pages
869-876
ISSN
  • 0887-0624 (ISSN-L)
  • 1520-5029
OpenAlex
W1978006186
Cited by
122
References
0
FWCI
1.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.