The DOI matches its Crossref record.
Characterization of Lead Leachability from Cathode Ray Tubes Using the Toxicity Characteristic Leaching Procedure
Abstract
Cathode ray tubes (CRTs) in television and computer monitors are one of the most common components of discarded electronics in the solid waste stream. CRTs present a disposal problem because of their growing magnitude in municipal solid waste (MSW) and their role as a major source of lead in MSW. Using the EPA Toxicity Characteristic Leaching Procedure (TCLP), lead leachability from CRTs was studied. Lead leached from the CRT samples at an average concentration of 18.5 mg/L. This exceeded the regulatory limit of 5.0 mg/L. Several factors affected the lead concentrations of each CRT sample. These included the sample fraction of the CRTs, the particle size used in the tests, and the CRT type. The most significant quantities of lead were obtained from the funnel portion of the CRTs at an average lead concentration of 75.3 mg/L. The major source of lead in the funnel is the frit seal of color CRTs. Samples containing the frit seal had lead leaching levels nearly 50 times those without. Samples comprised of smaller particle sizes exposed a greater surface area resulting in higher lead leaching levels. While 21 of 30 color CRTs exceeded regulatory lead limits, none of the six monochrome CRTs did. Age of the CRTs was not a significant factor for lead leaching. These results provide useful information to the regulatory and waste management community for developing policies for managing discarded CRTs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electronic waste management approaches: An overview
Kiddee, P., Naidu, R., & Wong, M. H. (2013) · Waste Management · doi:10.1016/j.wasman.2013.01.006 · Cited by 906
Nnorom, I. C., & Osibanjo, O. (2008) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2008.01.004 · Cited by 619
Chemical hazards associated with treatment of waste electrical and electronic equipment
Tsydenova, O., & Bengtsson, M. (2011) · Waste Management · doi:10.1016/j.wasman.2010.08.014 · Cited by 526
The challenge of electronic waste (e-waste) management in developing countries
Osibanjo, O., & Nnorom, I. C. (2007) · Waste Management & Research: The Journal for a Sustainable Circular Economy · doi:10.1177/0734242x07082028 · Cited by 372
Electronic waste (e-waste): Material flows and management practices in Nigeria
Nnorom, I. C., & Osibanjo, O. (2008) · Waste Management · doi:10.1016/j.wasman.2007.06.012 · Cited by 343
Cai, K., Song, Q., Peng, S., Yuan, W., Liang, Y., & Li, J. (2020) · Environmental Science and Pollution Research · doi:10.1007/s11356-019-06917-x · Cited by 62
Metadata
- Authors
- Musson, S. E., Jang, Y.-C., Townsend, T. G., & Chung, I.-H.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-09-07
- Volume
- 34
- Issue
- 20
- Pages
- 4376-4381
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W1964432353
- Cited by
- 190
- References
- 0
- FWCI
- 25.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.